Tips and Tricks of Inflatable Penile Prosthesis Reservoir Placement: A Case Presentation and Discussion
- 1 May 2014
- journal article
- case report
- Published by Oxford University Press (OUP) in The Journal of Sexual Medicine
- Vol. 11 (5) , 1325-1333
Abstract
Introduction: There have been many advances in the inflatable penile prosthesis (IPP) since the 1970s. While these devices were initially fraught with mechanical malfunction, the most recent models prove to be much more reliable. Although reservoir complications are not common, when they do occur, it typically involves damage to the surrounding tissues. The ability to recognize and treat these complications is paramount for any surgeon that routinely places IPPs. Aim: The aim of this article was to present a unique reservoir-related complication as well as perform a literature review of reservoir-related complications and techniques for reservoir placement, and provide a summary of dimensions and technical aspects of commonly used reservoirs. Methods: We reviewed a unique reservoir-related complication that presented to our institution with urinary retention and constipation. We also reviewed reservoir-related complications since 1984, reviewed the most recent surgical techniques involved in reservoir placement, and summarized the dimensions and technical characteristics of both the American Medical System® and Coloplast® reservoirs. Main Outcome Measure: A reservoir-related complication that resulted in urinary retention and constipation is the main outcome measure. Results: Although uncommon, reservoir complications do occur. The most common case report complication in the published literature is bladder erosion followed by external iliac compression, ileal conduit erosion, and small bowel obstruction. The case that presented at our institution was the result of a reservoir that was improperly placed in the perineum, causing urinary retention and constipation due to the compression of the bulbar urethra and rectum. Conclusions: In this era, mechanical failures of IPP reservoirs are rare as most complications occur due to damage of the surrounding tissues. Prevention, diagnosis, and treatment of these complications are important for any surgeon that implants IPPs.Keywords
This publication has 40 references indexed in Scilit:
- Centers of Excellence Concept and Penile Prostheses: An Outcome AnalysisJournal of Urology, 2009
- Penile prosthesis implantation: past, present and futureInternational Journal Of Impotence Research, 2008
- Long-Term Mechanical Reliability of AMS 700CX™/CXM Inflatable Penile ProsthesisJournal of Urology, 2006
- Historical advances in penile prosthesesInternational Journal Of Impotence Research, 2000
- Erosion of an Inflatable Penile Prosthesis Reservoir into the Bladder, Presenting as Bladder CalculiJournal of Urology, 1988
- Salvage of the Eroded Inflatable Penile Prosthesis: A New ConceptJournal of Urology, 1987
- Erosion of Inflatable Penile Prosthesis Reservoir Into BladderJournal of Urology, 1986
- Erosion of Inflatable Penile Prosthesis Reservoir into Bladder and BowelJournal of Urology, 1984
- Treatment of Organic Impotence by Implantation of a Penile ProsthesisJournal of Urology, 1967
- Surgical Treatment of ImpotencePlastic and Reconstructive Surgery, 1966