Immunosensor Based on Zinc Oxide Nanocrystals Decorated with Copper for the Electrochemical Detection of Human Salivary Alpha-Amylase
Authors:
- Beatriz Rodrigues MartinsBMBeatriz Rodrigues Martins
- Tainá Marques SampaioTSTainá Marques Sampaio
- Ana Karoline Silva Rocha de FariasAFAna Karoline Silva Rocha de Farias
- Rheltheer de Paula MartinsRMRheltheer de Paula Martins
- Renata Roland TeixeiraRTRenata Roland Teixeira
- Robson Tadeu Soares OliveiraRORobson Tadeu Soares Oliveira
- Carlo Jose Freire OliveiraCOCarlo Jose Freire Oliveira
- Marcos Vinícius da SilvaMarcos Vinícius da Silva
- Virmondes RodriguesVRVirmondes Rodrigues
- Noelio Oliveira DantasNDNoelio Oliveira Dantas
- Foued Salmen EspindolaFoued Salmen Espindola
- Anielle Christine Almeida SilvaAnielle Christine Almeida Silva
Open Access
- 3 June 2021
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 12 (6) , 657
Abstract
(1) Background: Nanocrystals (NCs)-based electrochemical sensors have been proposed for biomarkers detection, although immunosensors using ZnO NCs decorated with copper are still scarce. (2) Methods: Electrochemical immunodetection of human salivary alpha-amylase (HSA) used ZnO, CuO, and ZnO:xCu (x = 0.1, 0.4, 1.0, 4.0, and 12.0) NCs. (3) Results: Substitutional incorporation of Cu2+ in the crystalline structure of ZnO and formation of nanocomposite were demonstrated by characterization. Graphite electrodes were used and the electrochemical signal increased by 40% when using ZnO:1Cu and 4Cu (0.25 mg·mL−1), in an immunosensor (0.372 mg·mL−1 of anti-alpha-amylase and 1% of casein). Different interactions of HSA with the alpha-amylase antibody were registered when adding the NCs together, either before or after the addition of saliva (4 μL). The immunosensor changed specificity due to the interaction of copper. The ZnO:1Cu and ZnO:4Cu samples showed 50% interference in detection when used before the addition of saliva. The immunosensor showed 100% specificity and a sensitivity of 0.00196 U·mL−1. (4) Conclusions: Results showed that the order of NCs addition in the sensors should be tested and evaluated to avoid misinterpretation in detection and to enable advances in the validation of the immunosensor.Keywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de Minas Gerais (NS: ES08310 Project APQ-01083-16)
This publication has 58 references indexed in Scilit:
- The fascinating world of nanoparticle researchMaterials Today, 2013
- Highly sensitive and selective voltammetric detection of mercury(II) using an ITO electrode modified with 5-methyl-2-thiouracil, graphene oxide and gold nanoparticlesMicrochimica Acta, 2013
- ZnO nanowire lasersNanoscale, 2011
- Characterization of Nanomaterials by Physical MethodsAnnual Review of Analytical Chemistry, 2009
- Interaction of Copper and Human Salivary ProteinsJournal of Agricultural and Food Chemistry, 2009
- Nanoparticles—a historical perspectiveInternational Journal of Pharmaceutics, 2007
- Hand-held monitor of sympathetic nervous system using salivary amylase activity and its validation by driver fatigue assessmentBiosensors and Bioelectronics, 2006
- The ideal ceramic-fibre/oxide-matrix composite: how to reconcile antagonist physical and chemical requirements?European Journal of Control, 2005
- Differential Regulation of a Hyperthermophilic α-Amylase with a Novel (Ca,Zn) Two-metal Center by ZincJournal of Biological Chemistry, 2003
- Metal and anion binding sites in lactoferrin and related proteinsPure and Applied Chemistry, 1990