Design and operation of a hard x-ray transmissive single-shot spectrometer at LCLS
- 23 March 2013
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (5) , 052033
Abstract
We describe the design and operation of a transmissive single-shot spectrometer for the measurement of hard x-ray free electron laser (FEL) source spectrum at the Linac Coherent Light Source (LCLS). The spectrometer was built around a 10 μm thick near-perfect silicon single crystal that was cylindrically bent. Its energy range covered the full FEL bandwidth while its resolution was sufficient for resolving single spectral spikes characteristics of the FELs. Its application will not only greatly facilitate the understanding and optimization of the x-ray FEL sources, but can also serve as an invaluable inline diagnostic tool for experiments where the spectral content of the source plays an important role in data interpretation.Keywords
This publication has 8 references indexed in Scilit:
- A single-shot transmissive spectrometer for hard x-ray free electron lasersApplied Physics Letters, 2012
- A compact X-ray free-electron laser emitting in the sub-ångström regionNature Photonics, 2012
- High wavevector temporal speckle correlations at the Linac Coherent Light Source.Optics Express, 2012
- The soft x-ray instrument for materials studies at the linac coherent light source x-ray free-electron laserReview of Scientific Instruments, 2012
- First lasing and operation of an ångstrom-wavelength free-electron laserNature Photonics, 2010
- Monochromator beamline for FLASHReview of Scientific Instruments, 2006
- Statistical properties of the radiation from SASE FEL operating in the linear regimeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998
- Collective instabilities and high-gain regime in a free electron laserOptics Communications, 1984