Simultaneous Determination of Escitalopram Impurities including the R-enantiomer on a Cellulose tris(3,5-Dimethylphenylcarbamate)-Based Chiral Column in Reversed-Phase Mode
Open Access
- 17 December 2022
- Vol. 27 (24) , 9022
Abstract
A high-performance liquid chromatographic method was developed for the simultaneous determination of the related substances—three potential synthesis-related chemical impurities and the distomer—of escitalopram. The separation capacity of seven different polysaccharide-type chiral columns, including three amylose-based (Lux Amylose-1, Lux i-Amylose-1, Lux Amylose-2) and four cellulose-based columns (Lux Cellulose-1, Lux Cellulose-2, Lux Cellulose-3, and Lux Cellulose-4) were screened in the polar organic and reversed-phase modes. Lux Cellulose-1, based on cellulose tris(3,5-dimethylphenylcarbamate) as the chiral selector with an acetonitrile-water mixture containing 0.1% diethylamine was identified as the most promising separation system. Using the “one factor at a time” optimization approach, the effect of column temperature, flow rate, and mobile phase constituents on separation performance was evaluated, and the critical resolution values were determined. A U-shaped retention pattern was obtained when plotting the retention factors of the citalopram enantiomers versus the water content of the binary mobile phases on the Lux Cellulose-1 column. A thermodynamic analysis revealed enthalpy-driven enantioseparation in both the polar organic and reversed-phase modes. For further method optimizations, an L9 orthogonal array table was employed. Using the optimized parameters (Lux Cellulose-1 column with 0.1% (v/v) diethylamine in water/acetonitrile 55/45 (v/v); 0.8 mL/min flow rate at 25 °C), baseline separations were achieved between all compounds. Our newly developed HPLC method was validated according to the ICH guidelines and its application was tested with a commercially available pharmaceutical formulation. The method proved to be suitable for routine quality control of related substances and the enantiomeric purity of escitalopram.Keywords
Funding Information
- János Bolyai Research Scholarship of the Hungarian Academy of Sciences (10127/3/17.12.2020)
- Bolyai + New National Excellence Program of the Ministry for Innovation and Technology (10127/3/17.12.2020)
- University of Medicine, Pharmacy, Science and Technology, George Emil Palade of Târgu Mureș Research (10127/3/17.12.2020)
This publication has 35 references indexed in Scilit:
- Direct high-performance liquid chromatographic enantioseparation of secondary amino acids on Cinchona alkaloid-based chiral zwitterionic stationary phases. Unusual temperature behaviorJournal of Chromatography A, 2014
- HPLC Method for Chiral Separation and Quantification of Antidepressant Citalopram and Its Precursor CitadiolChromatographia, 2013
- Escitalopram, an antidepressant with an allosteric effect at the serotonin transporter—a review of current understanding of its mechanism of actionPsychopharmacology, 2011
- EscitalopramCNS Drugs, 2010
- Development and validation of a capillary electrophoresis method for the simultaneous determination of impurities of escitalopram including the R-enantiomerJournal of Pharmaceutical and Biomedical Analysis, 2008
- Development and validation of a liquid chromatographic method for determination of enantiomeric purity of citalopram in bulk drugs and pharmaceuticalsJournal of Pharmaceutical and Biomedical Analysis, 2006
- Escitalopram versus citalopram: the surprising role of the R-enantiomerPsychopharmacology, 2004
- Enantiomeric separation of citalopram and its metabolites by capillary electrophoresisElectrophoresis, 2003
- Determination of citalopram enantiomers in human plasma by liquid chromatographic separation on a Chiral-AGP columnJournal of Chromatography B: Biomedical Sciences and Applications, 1996
- Determination of the enantiomers of citalopram, its demethylated and propionic acid metabolites in human plasma by chiral HPLCChirality, 1995