Micelles of Mixed Pluronic Polymers ( P123 / P407 ) Enhanced Water Solubility and In Vitro Cytotoxicity of Apigenin in Breast, Ovarian, Pancreatic, Glioblastoma, and Drug‐Resistant Ovarian Cancers

Authors:

Abstract
Apigenin (4′,5,7‐trihydroxy flavone) is a plant‐derived flavonoid that has been shown to possess anti‐inflammatory, free radical scavenging, and anticancer activities. However, apigenin is poorly water‐soluble and has low bioavailability. The objective of the present study was to formulate and evaluate a polymeric micellar delivery system of apigenin for improved solubility and drug delivery in different cancers. Apigenin‐loaded mixed polymeric micelles composed of Pluronic polymers (P123 and P407) were prepared by the thin film hydration method. The micelles were characterized for the solubility of apigenin, particle size, zeta potential, critical micelle concentration (CMC), drug loading, encapsulation efficiency, and in vitro release study. The in vitro cytotoxicity of the micelles was studied in MCF‐7 and MDA MB 231, breast cancer cell lines; SKOV‐3, an ovarian cancer cell line; AsPC‐1, a pancreatic cancer cell line; U‐87, a glioblastoma cell line; and NCI/ADR, a drug‐resistant ovarian cancer cell line, using the MTT assay. The Pluronic polymers, P123 and P407, in the molar ratio of 9:1 gave an optimized micellar formulation containing apigenin. The average particle size of the micelles was 87.37 ± 6.75 nm with a polydispersity index of 0.305 ± 0.011, and the zeta potential was −18.19 ± 3.55 mV. The percentage drug loading and encapsulation efficiency were 1.84% ± 0.06% and 92.17% ± 2.96%, respectively. The solubility of apigenin in micelles was 0.901 mg/mL, which was about 143‐fold higher than that of pure apigenin in water. The micelles had a low CMC indicating their stability in aqueous media. The micelles sustained the release of apigenin for more than 48 h. MTT assay for in vitro cytotoxicity showed that apigenin‐loaded polymeric mixed micelles are more effective than pure apigenin in all the cancer cell lines tested. The IC 50 value of micelles was 4.5‐, 1.55‐, 3.96‐, 1.4‐, 3.66‐, and 3.76‐fold less in MCF‐7, MDA‐MB‐231, AsPC‐1, NCI/ADR, SKOV‐3, and U‐87 cell lines, respectively, than the free drug. Apigenin‐loaded Pluronic P123/P407 mixed micelles might be considered as an effective delivery system for the treatment of different cancers. However, in vivo biological activity and mechanistic study for anticancer potential should be explored in the future.
Funding Information
  • University Grants Commission (5‐63/2016‐IC)
  • King Saud University
  • Department of Health Research, India (R.12013/43/2024‐HR)

This publication has 40 references indexed in Scilit: