Validation of a Capillary Electrophoresis Method for the Simultaneous Determination of Amlodipine Besylate and Valsartan in Pharmaceuticals and Human Plasma
Open Access
- 1 March 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 94 (2) , 498-502
Abstract
A rapid, simple, and sensitive capillary electrophoresis (CE) method was developed and validated for the simultaneous determination of amlodipine (AML) and valsartan (VAL) in pharmaceuticals and human plasma using a UV photodiode array detector. Electrophoretic conditions were optimized to improve separation, sensitivity, and rapidity. The optimal conditions were 25 mM phosphate buffer at pH 8.0, injection time 10.0 s, voltage 25 kV, and column temperature 25C, with detection at 214 nm. The method was found to be linear in the range of 1.035 and 1.0350 mg/L, with weighted regression 0.9999 and 0.9994, for AML and VAL, respectively. Validation of the method showed acceptable intraday and interday accuracy (85.595.3) and precision (RSD 1.644.2) in pharmaceutical formulation and human plasma analysis. The sensitivity of the method was enhanced by both optimization of the CE procedure and preconcentration performed by liquidliquid extraction. The LOD for both AML and VAL was 0.03 mg/L, which allows analysis at the level of the drugs possibly found in human plasma. Therefore, the proposed method is suitable for QC in pharmaceutical laboratories and therapeutic drug monitoring in clinical laboratories.Keywords
This publication has 9 references indexed in Scilit:
- Electroanalytical Studies and Simultaneous Determination of Amlodipine Besylate and Atorvastatine Calcium in Binary Mixtures Using First Derivative of the Ratio‐Voltammetric MethodsElectroanalysis, 2009
- RP-LC Simultaneous Determination of Nebivolol Hydrochloride and Amlodipine Besilate in Bi-Layer TabletsChromatographia, 2009
- Development and validation of a highly sensitive and robust LC‐ESI‐MS/MS method for simultaneous quantitation of simvastatin acid, amlodipine and valsartan in human plasma: application to a clinical pharmacokinetic studyBiomedical Chromatography, 2009
- Simultaneous LC–MS–MS Analysis of Valsartan and Hydrochlorothiazide in Human PlasmaChromatographia, 2009
- A Validated RP–LC Method for Simultaneous Determination of Losartan Potassium and Amlodipine Besilate in Pharmaceutical PreparationsChromatographia, 2009
- Development of a stability‐indicating CE assay for the determination of amlodipine enantiomers in commercial tabletsElectrophoresis, 2008
- Validated TLC Method for Simultaneous Quantitation of Amlodipine Besylate and Valsartan in Bulk Drug and FormulationChromatographia, 2008
- Simultaneous CE Determination of Captopril and Indapamide in Pharmaceuticals and Human PlasmaChromatographia, 2008
- Development and validation of a method for quantitative determination of valsartan in human plasma by liquid chromatography-tandem mass spectrometryJournal of Pharmaceutical and Biomedical Analysis, 2007