MIFlowCyt‐EV: a framework for standardized reporting of extracellular vesicle flow cytometry experiments
Top Cited Papers
Open Access
- 3 February 2020
- journal article
- research article
- Published by Wiley in Journal of Extracellular Vesicles
- Vol. 9 (1) , 1713526
Abstract
Extracellular vesicles (EVs) are small, heterogeneous and difficult to measure. Flow cytometry (FC) is a key technology for the measurement of individual particles, but its application to the analysis of EVs and other submicron particles has presented many challenges and has produced a number of controversial results, in part due to limitations of instrument detection, lack of robust methods and ambiguities in how data should be interpreted. These complications are exacerbated by the field's lack of a robust reporting framework, and many EV‐FC manuscripts include incomplete descriptions of methods and results, contain artefacts stemming from an insufficient instrument sensitivity and inappropriate experimental design and lack appropriate calibration and standardization. To address these issues, a working group (WG) of EV‐FC researchers from ISEV, ISAC and ISTH, worked together as an EV‐FC WG and developed a consensus framework for the minimum information that should be provided regarding EV‐FC. This framework incorporates the existing Minimum Information for Studies of EVs (MISEV) guidelines and Minimum Information about a FC experiment (MIFlowCyt) standard in an EV‐FC‐specific reporting framework (MIFlowCyt‐EV) that supports reporting of critical information related to sample staining, EV detection and measurement and experimental design in manuscripts that report EV‐FC data. MIFlowCyt‐EV provides a structure for sharing EV‐FC results, but it does not prescribe specific protocols, as there will continue to be rapid evolution of instruments and methods for the foreseeable future. MIFlowCyt‐EV accommodates this evolution, while providing information needed to evaluate and compare different approaches. Because MIFlowCyt‐EV will ensure consistency in the manner of reporting of EV‐FC studies, over time we expect that adoption of MIFlowCyt‐EV as a standard for reporting EV‐ FC studies will improve the ability to quantitatively compare results from different laboratories and to support the development of new instruments and assays for improved measurement of EVs.Keywords
Funding Information
- Foundation for the National Institutes of Health
- National Cancer Institute (1ZIA-BC011502)
- National Institutes of Health (NIH UG3 TR002881)
- National Institutes of Health (U01-126497)
- National Institutes of Health (U01-OD-019750)
- National Institutes of Health (R01 CA218500)
- National Institutes of Health (R01 HL1266497)
- National Institutes of Health (UG3 TR002881)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (CANCER-ID 14195)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (VENI 15924)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (VENI 13681)
- Prostate Cancer Foundation
- Foundation for the National Institutes of Health (Pamela Cafritz Renal Cell Carcinoma Award)
- National Cancer Institute (1ZIA-BC011502)
- National Institutes of Health (NIH UG3 TR002881)
- National Institutes of Health (U01-126497; U01-OD-019750; R01 CA218500; R01 HL1266497; NIH UG3 TR002881)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (STW perspectief CANCER-ID 14195)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (VENI 15924)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (VENI 13681)
- ISAC (Marylou Ingram Scholar)
- ISAC (Mary Lou Ingram Scholar)
- Prostate Cancer Foundation (YIA)
This publication has 38 references indexed in Scilit:
- Standardization of pre-analytical variables in plasma microparticle determination: results of the International Society on Thrombosis and Haemostasis SSC Collaborative workshopJournal of Thrombosis and Haemostasis, 2013
- A trigger channel threshold artifact in nanoparticle analysisCytometry Part A, 2013
- Standardization of sample collection, isolation and analysis methods in extracellular vesicle researchJournal of Extracellular Vesicles, 2013
- FlowRepository: A resource of annotated flow cytometry datasets associated with peer‐reviewed publicationsCytometry Part A, 2012
- Quantitative and qualitative flow cytometric analysis of nanosized cell-derived membrane vesiclesNanomedicine: Nanotechnology, Biology and Medicine, 2012
- Fluorescent labeling of nano-sized vesicles released by cells and subsequent quantitative and qualitative analysis by high-resolution flow cytometryNature Protocols, 2012
- Single vs. swarm detection of microparticles and exosomes by flow cytometryJournal of Thrombosis and Haemostasis, 2012
- A new microparticle size calibration standard for use in measuring smaller microparticles using a new flow cytometerJournal of Thrombosis and Haemostasis, 2011
- Optical and non‐optical methods for detection and characterization of microparticles and exosomesJournal of Thrombosis and Haemostasis, 2010
- MIFlowCyt: The minimum information about a flow cytometry experimentCytometry Part A, 2008