Wavefront Ablation Profiles in Refractive Surgery: Description, Results, and Limitations
Authors:
- David SmadjaDSDavid Smadja
- Glauco Reggiani-MelloGRGlauco Reggiani-Mello
- Marcony R. SanthiagoMSMarcony R. Santhiago
- Ronald R. KruegerRKRonald R. Krueger
- 1 March 2012
- journal article
- review article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 28 (3) , 224-232
Abstract
PURPOSE: To provide an overview of the clinical results of different ablation profiles based on wavefront technology and discuss their characteristics and limitations. METHODS: Literature review of studies reporting results of ablation profiles based on wavefront technology in virgin healthy eyes. RESULTS: Over the past 10 years, a large number of studies comparing different treatment algorithms and newer excimer laser platforms have been published. Thirty-six clinical studies including 3637 eyes analyzing the clinical results obtained after wavefront-guided, wavefront-optimized, and Q-factor profiles have been reviewed. Although wavefront-driven profiles allowed reduction of the amount of induced optical aberrations with conventional ablations, thereby improving the quality of vision, it appears that no algorithm of treatment or excimer laser platform has demonstrated a clear superiority over another. Wound healing and unexpected biomechanical response to surgery affect the accuracy of customized treatments and produce variable results. In addition, it is difficult to rigorously analyze and compare findings among different studies because of the diverse variety in which the data are reported. CONCLUSIONS: Despite several technological improvements over the years, wavefront ablation profiles have not consistently demonstrated superiority in terms of visual acuity and lower order aberrations compared to the standard procedure, although the induction of higher order aberrations has been reduced. The concept of an individualized eye model has emerged recently, based on the optical ray tracing algorithm, and could theoretically provide a higher level of customization, thus fulfilling the promise of “super vision.”Keywords
This publication has 47 references indexed in Scilit:
- Meta‐Analysis of Wavefront‐Guided vs. Wavefront‐Optimized LASIK for MyopiaOptometry and Vision Science, 2011
- Corneal asphericity and spherical aberration after refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- LASIK for Myopic Astigmatism and Presbyopia Using Non-Linear Aspheric Micro-Monovision with the Carl Zeiss Meditec MEL 80 PlatformJournal of Refractive Surgery, 2011
- Enhanced Visual Acuity and Image Perception Following Correction of Highly Aberrated Eyes Using an Adaptive Optics Visual SimulatorJournal of Refractive Surgery, 2010
- Excimer laser correction of moderate to high astigmatism with a non-wavefront-guided aberration-free ablation profile: Six-month resultsJournal of Cataract & Refractive Surgery, 2009
- Comparison of Night Driving Performance after Wavefront-Guided and Conventional LASIK for Moderate MyopiaOphthalmology, 2009
- Wavefront-guided versus wavefront-optimized laser in situ keratomileusis: Contralateral comparative studyJournal of Cataract & Refractive Surgery, 2008
- Improved contrast sensitivity and visual acuity after wavefront-guided laser in situ keratomileusis: In-depth statistical analysisJournal of Cataract & Refractive Surgery, 2006
- Photorefractive keratectomy with aspheric profile of ablation versus conventional photorefractive keratectomy for myopia correctionJournal of Cataract & Refractive Surgery, 2006
- Wavefront analysis in post-LASIK eyes and its correlation with visual symptoms, refraction, and topographyOphthalmology, 2004