The impact of exercise on derived measures of central pressure and augmentation index obtained from the SphygmoCor device
Authors:
- Ellen A. DawsonEDEllen A. Dawson
- Mark A. BlackMBMark A. Black
- Jennifer PybisJPJennifer Pybis
- N. Timothy CableNCN. Timothy Cable
- Daniel J. GreenDGDaniel J. Green
Open Access
- 1 June 2009
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 106 (6) , 1896-1901
Abstract
The purpose of this study was to investigate whether measures derived from the SphygmoCor device and its associated transfer function are influenced by exercise-induced alterations in vascular tone. Measurements were taken from either the exercised or the contralateral nonexercised limb during repeated and identical incremental hand-grip protocols. Eight male subjects performed three 3-min bouts of hand-grip exercise on two occasions. The exercise intensities were set at 3 kg, 5 kg, with a final 1.5-kg bout performed during cuff ischemia (1.5Isch). Blood pressure waveforms were recorded from the radial artery of either the exercised or nonexercised limb using applanation tonometry (SphygmoCor) during a 90-s rest period immediately after each exercise bout. Central blood pressures and augmentation indexes (AIx), an index of arterial stiffness, were derived using the peripheral waveform and the inbuilt SphygmoCor transfer function (TF). AIx was consistently ∼10% higher in the exercised arm during all trials compared with the nonexercised limb. Similarly, there was a consistent and significant difference (∼3 mmHg; P < 0.05) between exercised and nonexercised arms for the derived central systolic and mean arterial blood pressures. Despite identical bouts of exercise, AIx and central systolic and mean arterial blood pressures derived from applanation tonometry at the peripheral radial artery were statistically different when assessed at the exercising arm vs. the nonexercising arm. Changes in vascular tone with exercise may modify the intrinsic characteristics of the vessel wall and could compromise the assumptions underlying transfer functions used to derive central measures using applanation tonometry.Keywords
This publication has 15 references indexed in Scilit:
- ANALYSIS OF SHORT-TERM REPRODUCIBILITY OF ARTERIAL VASOREACTIVITY BY PULSE-WAVE ANALYSIS AFTER PHARMACOLOGICAL CHALLENGEClinical and Experimental Pharmacology and Physiology, 2009
- Central Pressure: Variability and Impact of Cardiovascular Risk FactorsHypertension, 2008
- Exercise reduces arterial pressure augmentation through vasodilation of muscular arteries in humansAmerican Journal of Physiology-Heart and Circulatory Physiology, 2008
- Importance of Measuring the Time Course of Flow-Mediated Dilatation in HumansHypertension, 2008
- Wave reflection and central aortic pressure are increased in response to static and dynamic muscle contraction at comparable workloadsJournal of Applied Physiology, 2008
- A generalized arterial transfer function derived at rest underestimates augmentation of central pressure after exerciseJournal Of Hypertension, 2007
- Transmission of calibration errors (input) by generalized transfer functions to the aortic pressures (output) at different hemodynamic statesInternational Journal of Cardiology, 2006
- Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During ExerciseHypertension, 2006
- The effect of exercise on large artery haemodynamics in healthy young menEuropean Journal of Clinical Investigation, 2005
- Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in ManCirculation, 1968