From modeling to implementation of a method for restraining back relaxation in ionic polymer–metal composite soft actuators
- 24 July 2018
- journal article
- research article
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 29 (15) , 3124-3135
Abstract
Ionic polymer–metal composites are an emerging kind of electroactive polymer actuators, which can bend in response to a relatively low driving voltage. However, to enhance the actuation performance of ionic polymer–metal composites, some of their drawbacks should be considered. One of the most important drawbacks is “back relaxation.” The so-called back relaxation effect means, when a step input voltage is applied to the ionic polymer–metal composite, the conventional bending displacement toward the anode is followed by an unwanted and slow back relaxation toward the cathode. Control-based methods for restraining the ionic polymer–metal composite back relaxation effect are feedback-based schemes which apply significant constraints to dominant applications of ionic polymer–metal composite actuators especially in biomedical applications. In this article, we present an entirely scientific-based mathematical modeling to achieve a practical method for restraining the back relaxation effect in Nafion-based ionic polymer–metal composites, relying on creating a specific pattern on Pt layers of the ionic polymer–metal composites and applying a local Gaussian disturbance to this patterned ionic polymer–metal composites.Keywords
This publication has 43 references indexed in Scilit:
- Nonautoregressive Nonlinear Identification of IPMC in Large Deformation Situations Using Generalized Volterra-Based ApproachIEEE Transactions on Instrumentation and Measurement, 2016
- Restraining IPMC Back Relaxation in Large Bending Displacements: Applying Non-Feedback Local Gaussian Disturbance by Patterned ElectrodesIEEE Transactions on Electron Devices, 2016
- Non-uniform deformation and curvature identification of ionic polymer metal composite actuatorsJournal of Intelligent Material Systems and Structures, 2014
- Nonlinear identification of IPMC actuators based on ANFIS–NARX paradigmSensors and Actuators A: Physical, 2014
- Ionic Polymer-Metal Composites (IPMCs) as dexterous manipulators and tactile sensors for minimally invasive robotic surgery2012
- A Resonant Vibrating Tactile Probe for Biomedical Applications Based on IPMCIEEE Transactions on Instrumentation and Measurement, 2010
- Derivation of Transfer Function of an IPMC Actuator Based on Pseudo-Rigid Body ModelJournal of Reinforced Plastics and Composites, 2010
- Static and Dynamic Characterization of the Temperature and Humidity Influence on IPMC ActuatorsIEEE Transactions on Instrumentation and Measurement, 2009
- A Tactile Sensor for Biomedical Applications Based on IPMCsIEEE Sensors Journal, 2008
- Precision force and position control of an ionic polymer metal compositeProceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering, 2004