Safety and efficacy of the polymer enhanced AS-ELARIS® pedicle screw system using ultrasonically liquefied polylactide: a short-, mid-, and long-term posterolateral fusion study in sheep
Open Access
- 11 March 2026
- journal article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Abstract
Lumbar fusion surgery using pedicle screws and intervertebral cages is frequently performed to treat low back pain when conservative therapies were unsuccessful. Screw loosening, however, remains one of the most common postoperative complications. The purpose of this study was to show that the fixation with polymer-enhanced AS-ELARIS® Pedicle Screws by ultrasonic-assisted extrusion of 0.104 mL resorbable polylactide per screw, represents a suitable alternative to current fixation techniques. Forty adult female sheep were enrolled in the study and posterolateral fusions were performed at two non-adjacent lumbar levels (L1+L2, L4+L5), implanting eight AS-ELARIS® Pedicle Screws per animal. After a survival period of 2 days, 8 weeks, 6, 12 or 24 months, animals were sacrificed and the instrumented vertebrae harvested for macroscopic, radiological, and histological evaluation. Despite surgical challenges in achieving optimal screw positioning, all evaluations demonstrated good biocompatibility and progressive osseointegration. Ultrasonic liquefaction-mediated polymer enhancement proved safe at all investigated timepoints, without evidence of thermal or inflammatory tissue damage. The AS-ELARIS® Pedicle Screw System may offer a promising alternative to current fixation techniques. Its biocompatibility, biodegradability, safe removal, and ease of handling make it a valuable addition to spinal fixation strategies.Keywords
This publication has 40 references indexed in Scilit:
- Intraoperative biomechanics of lumbar pedicle screw loosening following successful arthrodesisJournal of Orthopaedic Research, 2017
- Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgeryArchives of orthopaedic and trauma surgery, 2016
- The use of BoneWelding® technology in spinal surgery: an experimental study in sheepEuropean Spine Journal, 2011
- Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentationClinical Biomechanics, 2011
- Enhancing the mechanical integrity of the implant–bone interface with BoneWelding® technology: Determination of quasi‐static interfacial strength and fatigue resistanceJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- Efficacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spineJournal of Orthopaedic Science, 2005
- Thermal analysis of bone cement polymerisation at the cement–bone interfaceJournal of Biomechanics, 2004
- Role of cortical and cancellous bone of the vertebral pedicle in implant fixationEuropean Spine Journal, 2001
- Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbitThe Journal of Prosthetic Dentistry, 1983
- Polylactic Acid for Surgical ImplantsArchives of Surgery, 1966