Inter‐rater reliability of the BIOCHIP indirect immunofluorescence dermatology mosaic in bullous pemphigoid and pemphigus patients
- 12 August 2019
- journal article
- research article
- Published by Wiley in Journal of the European Academy of Dermatology and Venereology
- Vol. 33 (12) , 2327-2333
Abstract
Background The BIOCHIP (Dermatology Mosaic 7; EUROIMMUN, Lubeck, Germany) is a novel multiplex indirect immunofluorescence (IIF) technique used in the serological diagnosis of bullous pemphigoid (BP) and pemphigus. Objective To validate the accuracy and inter-rater reliability (IRR) of the BIOCHIP in the diagnosis of BP, pemphigus foliaceus (PF) and pemphigus vulgaris (PV). Methods Sera from patients with BP (n = 38), PF (n = 8), PV (n = 23), control patients (n = 64) and healthy control volunteers (n = 39) were tested. Sera were collected and analysed during the course of the disease at 1-5 different time points. The BIOCHIP was performed for all patients, digital images were captured of each incubated field, and the images were shared with 10 dermatologists experienced in reading IF from around the world to report. There were 312 BIOCHIP slides consisting of 1872 photos in total. All patients were de-identified. Fleiss Kappa was used to estimate the IRR. Results Fleiss Kappa was computed for each category (Oesophagus, Oesophagus immunofluorescence pattern, Salt-Split Skin (SSS), SSS immunofluorescence location, BP180, BP230, Dsg 1 and Ds3). The inter-rater agreement between the 10 raters varied between fair and moderate for all categories. Those that demonstrated fair concordance included monkey oesophagus (k = 0.257, P < 0.0001), oesophagus pattern (k = 0.357, P < 0.0001), Dsg1 (k = 0.390, P < 0.0001) and BP230 (k = 0.281, P < 0.0001). Moderate agreement was demonstrated for SSS (k = 0.416, P < 0.0001), SSS immunofluorescence location (k = 0.505, P < 0.0001), Dsg3 (k = 0.437, P < 0.0001) and BP180 (k = 0.559, P < 0.0001). Conclusion The BIOCHIP mosaic-based immunofluorescence test is a simple, time and effort saving test that can aid in the diagnosis and screening of BP, PV and PF. However, the level of agreement was relatively low. The authors found the most common causes to be variable levels of training, indicating the presence of a learning curve in the interpretation of the results and ambiguous staining patterns leading to incongruent results.Keywords
This publication has 24 references indexed in Scilit:
- Serological diagnosis of autoimmune bullous skin diseases: Prospective comparison of the BIOCHIP mosaic-based indirect immunofluorescence technique with the conventional multi-step single test strategyOrphanet Journal of Rare Diseases, 2012
- Diagnosis and Clinical Features of Pemphigus FoliaceusDermatologic Clinics, 2011
- Clinical and immunopathological evaluation of epidermolysis bullosa acquisitaClinical and Experimental Dermatology, 2010
- Evaluation of a BP180-NC16a enzyme-linked immunosorbent assay in the initial diagnosis of bullous pemphigoidBritish Journal of Dermatology, 2004
- Characterization of the Anti-BP180 Autoantibody Reactivity Profile and Epitope Mapping in Bullous Pemphigoid Patients11Tables 1, 2, 3 and 5 can be found at http://www.blackwellpublishing.com/products/journals/suppmat/jid/jid22126/jid22126sm.htmJournal of Investigative Dermatology, 2004
- Usefulness of enzyme-linked immunosorbent assay using recombinant desmogleins 1 and 3 for serodiagnosis of pemphigusBritish Journal of Dermatology, 1999
- Cloning and Primary Structural Analysis of the Bullous Pemphigoid Autoantigen BP180Journal of Investigative Dermatology, 1992
- Isolation of complementary DNA for bullous pemphigoid antigen by use of patients' autoantibodies.Journal of Clinical Investigation, 1988
- Measuring nominal scale agreement among many raters.Psychological Bulletin, 1971
- Measures of response agreement for qualitative data: Some generalizations and alternatives.Psychological Bulletin, 1971