POCS‐based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion‐related artifacts
- 13 November 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 74 (5) , 1336-1348
Abstract
Purpose: A projection onto convex sets reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE) is developed to reduce motion‐related artifacts, including respiration artifacts in abdominal imaging and aliasing artifacts in interleaved diffusion‐weighted imaging.Theory: Images with reduced artifacts are reconstructed with an iterative projection onto convex sets (POCS) procedure that uses the coil sensitivity profile as a constraint. This method can be applied to data obtained with different pulse sequences and k‐space trajectories. In addition, various constraints can be incorporated to stabilize the reconstruction of ill‐conditioned matrices.Methods: The POCSMUSE technique was applied to abdominal fast spin‐echo imaging data, and its effectiveness in respiratory‐triggered scans was evaluated. The POCSMUSE method was also applied to reduce aliasing artifacts due to shot‐to‐shot phase variations in interleaved diffusion‐weighted imaging data corresponding to different k‐space trajectories and matrix condition numbers.Results: Experimental results show that the POCSMUSE technique can effectively reduce motion‐related artifacts in data obtained with different pulse sequences, k‐space trajectories and contrasts.Conclusion: POCSMUSE is a general post‐processing algorithm for reduction of motion‐related artifacts. It is compatible with different pulse sequences, and can also be used to further reduce residual artifacts in data produced by existing motion artifact reduction methods. Magn Reson Med 74:1336–1348, 2015.Keywords
Funding Information
- NIH (R01 NS-074045, R21 EB-018419)
This publication has 32 references indexed in Scilit:
- High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 TMagnetic Resonance in Medicine, 2012
- Two‐dimensional phase cycled reconstruction for inherent correction of echo‐planar imaging nyquist artifactsMagnetic Resonance in Medicine, 2011
- High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE)NeuroImage, 2010
- Nonlinear phase correction of navigated multi‐coil diffusion imagesMagnetic Resonance in Medicine, 2006
- Propeller EPI in the other directionMagnetic Resonance in Medicine, 2006
- Simultaneous phase correction and SENSE reconstruction for navigated multi‐shot DWI with non‐cartesian k‐space samplingMagnetic Resonance in Medicine, 2005
- Nonlinear phase correction for navigated diffusion imagingMagnetic Resonance in Medicine, 2003
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- A fast, iterative, partial-fourier technique capable of local phase recoveryJournal of Magnetic Resonance (1969), 1991