Abstract
Electroanatomic mapping (EAM) systems facilitate the elimination of fluoroscopy during electrophysiologic (EP) studies and ablations. The rate and predictors of fluoroscopy requirements while attempting fluoroscopy-free (FF) ablations are unclear. This study aimed (1) to investigate the rates of fluoroscopic use and acute success in patients initially referred for FF ablation and (2) to identify procedural characteristics associated with fluoroscopic use in patients in whom FF ablation was initially planned (IFF). We performed a retrospective review of all patients who underwent IFF EP study or ablation between 2010 and 2013. Patient and procedural characteristics were compared between those with successful FF procedures and those who subsequently required fluoroscopy during their procedure. An FF EP study with or without ablation was performed in 124 patients during 138 procedures for either supraventricular or idiopathic ventricular arrhythmias. Of the 138 procedures, 105 of them were performed without fluoroscopy. In the remaining 33 cases, fluoroscopy was used for an average of 1.21 minutes ± 1.18 minutes. Acute procedural success was achieved in 97% of both FF and fluoroscopy procedures. The primary reason for fluoroscopy use was as a guide for transseptal puncture. There were no significant differences between FF and fluoroscopy procedures with respect to catheter placement time or complication rate. In conclusion, in this single-center study of IFF procedures, despite careful case selection for IFF ablation, 24% of IFF cases ultimately required minimal fluoroscopy. Fluoroscopy and FF procedures had similar rates of procedural success and complications. Additional large prospective studies are required to further investigate the safety and efficacy of FF ablations.Keywords
This publication has 14 references indexed in Scilit:
- Brain and Neck Tumors Among Physicians Performing Interventional ProceduresThe American Journal of Cardiology, 2013
- Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking systemEP Europace, 2012
- Nonfluoroscopic Catheter Ablation of Cardiac Arrhythmias in Adults: Feasibility, Safety, and EfficacyJournal of Cardiovascular Electrophysiology, 2012
- “Near-zero” fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literatureJournal of Interventional Cardiac Electrophysiology, 2011
- Learning Curve for Zero‐Fluoroscopy Catheter Ablation of AVNRT: Early versus Late ExperiencePacing and Clinical Electrophysiology, 2010
- Safety and feasibility of catheter ablation for atrioventricular nodal re-entrant tachycardia without fluoroscopic guidanceHeart Rhythm, 2009
- Image integration using NavX fusion: Initial experience and validationHeart Rhythm, 2008
- Nonfluoroscopic Catheter Navigation for Radiofrequency Catheter Ablation of Supraventricular Tachycardia in ChildrenPacing and Clinical Electrophysiology, 2006
- Three‐Dimensional Mapping in Interventional Electrophysiology: Techniques and TechnologyJournal of Cardiovascular Electrophysiology, 2005
- Occupational hazards of interventional cardiologists: Prevalence of orthopedic health problems in contemporary practiceCatheterization and Cardiovascular Interventions, 2004