Monitoring of positron using high-energy gamma camera for proton therapy
- 5 December 2014
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 29 (3) , 268-275
Abstract
In proton therapy, imaging of proton-induced positrons is a useful method to monitor the proton beam distribution after therapy. Usually, a positron emission tomography (PET) system installed in or near the proton beam treatment room is used for this purpose. However, a PET system is sometimes too large and expensive for this purpose. We developed a small field-of-view (FOV) gamma camera for high-energy gamma photons and used it for monitoring the proton-induced positron distribution. The gamma camera used 0.85 mm × 0.85 mm × 10 mm Ce:Gd3Al2Ga3O12 (GAGG) pixels arranged in 20 × 20 matrix to form a scintillator block, which was optically coupled to a 1-inch-square position-sensitive photomultiplier tube (PSPMT). The GAGG detector was encased in a 20-mm thick container and a pinhole collimator was mounted on its front. The gamma camera was set 1.2 m from the 35 cm × 35 cm × 5 cm plastic phantom in the proton therapy treatment room, and proton beams were irradiated to the phantom with two proton energies. The gamma camera had spatial resolution of ~6.7 cm and sensitivity of 3.2 × 10−7 at 1 m from the collimator surface. For both proton energies, positron distribution in the phantom could be imaged by the gamma camera with 10-min acquisition. The lengths of the range of protons measured from the images were almost identical to the simulation results. These results indicate that the developed high-energy gamma camera is useful for imaging positron distributions in proton therapy.Keywords
This publication has 19 references indexed in Scilit:
- 2inch diameter single crystal growth and scintillation properties of Ce:Gd3Al2Ga3O12Journal of Crystal Growth, 2012
- A single-ring OpenPET enabling PET imaging during radiotherapyPhysics in Medicine & Biology, 2012
- Physical and clinical performance of the mCT time-of-flight PET/CT scannerPhysics in Medicine & Biology, 2011
- Development of a small prototype for a proof-of-concept of OpenPET imagingPhysics in Medicine & Biology, 2011
- Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Quantitative comparison of suitability of various beams for range monitoring with induced β+activity in hadron therapyPhysics in Medicine & Biology, 2005
- Performance evaluation of the new whole-body PET/CT scanner: Discovery STEuropean Journal of Nuclear Medicine and Molecular Imaging, 2004
- In-beam PET measurements of β+radioactivity induced by proton beamsPhysics in Medicine & Biology, 2001
- Proton dose monitoring with PET: quantitative studies in LucitePhysics in Medicine & Biology, 1996
- Visualization and Transport of Positron Emission from Proton Activation in vivoScience, 1978