Iterative refinement of the minimum norm solution of the bioelectric inverse problem
Author:
- 1 May 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 43 (5) , 547-552
Abstract
Functional brain imaging based on the bioelectric scalp field depends on the solution of the inverse problem. The object is to estimate the current distribution in the cortex from a measured noisy scalp potential field. A minimum norm least squares solution is often used for this purpose. Although this approach leads to a unique solution, it represents only one of a set of feasible solutions. In particular, it leads to a solution in which current is found to be generated widely in the cortex. There are other feasible minimum norm solutions for which cortical current is generated only in a restricted region, and it is likely that in many cases, these solutions are of physiological importance. This study presents a method to uncover these solutions. It is based on the idea that a minimum norm solution can be used to define a region of interest, an ellipsoid, within which it is worthwhile to search for another feasible solution. The minimum norm approach is used iteratively and the ellipsoid shrinks. As it shrinks it provides evidence pointing to the location of the active cortical region. The method explicitly recognizes the role of measurement noise in defining feasible solutions. It is tested in a model of the human head that incorporates a realistic cortex in a three-shell sphere. The method improves the localization of cortical activity mimicking physiological processing.Keywords
This publication has 13 references indexed in Scilit:
- Magnetic source images determined by a lead-field analysis: the unique minimum-norm least-squares estimationIEEE Transactions on Biomedical Engineering, 1992
- Do humans see what monkeys see?Trends in Neurosciences, 1992
- Iterative methods for image deblurringProceedings of the IEEE, 1990
- Realistic modeling of vep topographyVision Research, 1990
- Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp ThicknessesIEEE Transactions on Biomedical Engineering, 1981
- Practical Approximate Solutions to Linear Operator Equations When the Data are NoisySIAM Journal on Numerical Analysis, 1977
- Eccentric Dipole in a Spherical Medium: Generalized Expression for Surface PotentialsIEEE Transactions on Biomedical Engineering, 1973
- EEG Electrode Sensitivity-An Application of ReciprocityIEEE Transactions on Biomedical Engineering, 1969
- Smoothing by spline functionsNumerische Mathematik, 1967
- The (±) Reference: Accuracy of Estimated Mean Components in Average Response StudiesScience, 1967