Fast Internal Temperature Measurements in PBX9501 Thermal Explosions

Authors:

Abstract
We have made spatially and temporally resolved temperature measurements internal to a thermal explosion in PBX9501, which is a plastic bonded explosive composed of 95% HMX and 2.5% estane mixed with 2.5% nitroplasticizer (BDNPA/F). In order to study the evolution of ignition in a thermally treated piece of explosive, we have pushed the time resolution of several different temperature diagnostics. In this paper, we will discuss the details of the time response of these diagnostics including temperature uncertainties. The temperature measurements are made both by thermocouples with corrections applied to compensate for the thermocouple response time and with optical pyrometry. An additional goal of adding high energy radiography diagnostics to future experiments has motivated an effort to synchronize thermal explosions to an external clock. In this paper, I discuss our current capabilities for controlling and measuring the development of an ignition within a piece of heated PBX9501.