Impact of retention on trans‐column velocity biases in packed columns
- 14 December 2009
- journal article
- separations
- Published by Wiley in AIChE Journal
- Vol. 56 (6) , 1495-1509
Abstract
The heights equivalent to a theoretical plate of a weakly and strongly retained compounds were measured on two packed columns having different average mesopore sizes. The measurements were carried out in two different cases, with access to the mesopores by the sample molecules blocked (filled with n‐nonane) or not. The experimental results demonstrate that the eddy dispersion terms of both columns are significantly smaller for porous than for nonporous particles. Two simultaneous phenomena explain this observation. First, packed columns are radially heterogeneous which causes significant trans‐column velocity biases warping the bands. Second, radial dispersion contributes to mass transfer across the column, relaxing the radial concentration gradients that are caused by these velocity biases. The impact of these biases is minimized when the pores of the particles are not blocked; it decreases with increasing residence time and radial dispersion coefficient of the solutes. © 2009 American Institute of Chemical Engineers AIChE J, 2009Keywords
Funding Information
- National Science Foundation (CHE-06-08659)
- University of Tennessee
- Oak Ridge National Laboratory
This publication has 41 references indexed in Scilit:
- Mass Transfer Equation for Proteins in Very High-Pressure Liquid ChromatographyAnalytical Chemistry, 2009
- Peak Parking−Moment Analysis. A Strategy for the Study of the Mass-Transfer Kinetics in the Stationary PhaseAnalytical Chemistry, 2007
- General HETP Equation for the Study of Mass-Transfer Mechanisms in RPLCAnalytical Chemistry, 2006
- Surface Diffusion of Alkylbenzenes on Octadecylsilyl−Silica GelIndustrial & Engineering Chemistry Research, 1998
- Contribution of the Radial Distribution of the Flow Velocity to Band Broadening in HPLC ColumnsAnalytical Chemistry, 1997
- Radial distribution of the flow velocity, efficiency and concentration in a wide HPLC columnAIChE Journal, 1997
- Measurement of transverse and axial apparent dispersion coefficients in packed bedsAIChE Journal, 1996
- Diffusion study at 25.deg. with a shearing diffusiometer. Comparison with the Gouy and conductance methodsJournal of the American Chemical Society, 1970
- On the dispersion of a solute in a fluid flowing through a tubeProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1956
- Correlation of diffusion coefficients in dilute solutionsAIChE Journal, 1955