Camera-Derived Photoplethysmography (rPPG) and Speckle Plethysmography (rSPG): Comparing Reflective and Transmissive Mode at Various Integration Times Using LEDs and Lasers
Open Access
Abstract
Background: Although both speckle plethysmography (SPG) and photoplethysmography (PPG) examine pulsatile changes in the vasculature using opto-electronics, PPG has a long history, whereas SPG is relatively new and less explored. The aim of this study was to compare the effects of integration time and light-source coherence on signal quality and waveform morphology for reflective and transmissive rSPG and rPPG. Methods: (A) Using time-domain multiplexing, we illuminated 10 human index fingers with pulsed lasers versus LEDs (both at 639 and 850 nm), in transmissive versus reflective mode. A synchronized camera (Basler acA2000-340 km, 25 cm distance, 200 fps) captured and demultiplexed four video channels (50 fps/channel) in four stages defined by illumination mode. From all video channels, we derived rPPG and rSPG, and applied a signal quality index (SQI, scale: Good > 0.95; Medium 0.95–0.85; Low 0.85–0.8; Negligible < 0.8); (B) For transmission videos only, we additionally calculated the intensity threshold area (ITA), as the area of the imaging exceeding a certain intensity value and used linear regression analysis to understand unexpected similarities between rPPG and rSPG. Results: All mean SQI-values. Reflective mode: Laser-rSPG > 0.965, LED-rSPG < 0.78, rPPG < 0.845. Transmissive mode: 0.853–0.989 for rSPG and rPPG at all illumination settings. Coherent mode: Reflective rSPG > 0.951, reflective rPPG < 0.740, transmissive rSPG and rPPG 0.990–0.898. Incoherent mode: Reflective all 2 values of rPPG with rSPG (R2 = 0.99) and ITA (R2 = 0.98); Discussion: Laser-rSPG and LED-rPPG produced different waveforms in reflection, but not in transmission. We created the concept of ITA to investigate this behavior. Conclusions: Reflective Laser-SPG truly originated from coherence. Transmissive Laser-rSPG showed a loss of speckles, accompanied by waveform changes towards rPPG. Diffuse spatial intensity modulation polluted spatial-mode SPG.Keywords
This publication has 17 references indexed in Scilit:
- Comparison of speckleplethysmographic (SPG) and photoplethysmographic (PPG) imaging by Monte Carlo simulations and in vivo measurementsBiomedical Optics Express, 2018
- Wearable speckle plethysmography (SPG) for characterizing microvascular flow and resistanceBiomedical Optics Express, 2018
- Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumptionJournal of Biomedical Optics, 2018
- Imaging microvascular flow characteristics using laser speckle contrast imaging2010
- Multiwavelength Pulse Oximetry: Theory for the FutureAnesthesia & Analgesia, 2007
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- Determination of optimal exposure time for imaging of blood flow changes with laser speckle contrast imagingApplied Optics, 2005
- THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPHAmerican Journal of Physiology-Legacy Content, 1938
- Lichtelektrische PlethysmogrammeJournal of Molecular Medicine, 1938
- Photoelectric Plethysmography of the Fingers and Toes in ManExperimental Biology and Medicine, 1937