Self-Steering Catheters for Neuroendovascular Interventions
Open Access
- 19 September 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (4) , 1726-1737
Abstract
The size limitations and tortuosity of the neurovasculature currently exceed the capabilities of existing robotic systems. Furthermore, safety considerations require a fail-safe design whereby some passive compliance is used for an added layer of safety and for sensing the lateral load on the steerable portion of the catheter. To address these needs, we propose a novel multi-articulated robotic catheter technology that aims to increase technical precision, reduce procedural time and radiation exposure, and enable the semi-automation of catheters during neuroendovascular procedures. This catheter uses joint-level sensing and fluoroscopic imaging to actively bend in two separate planes. Its design also uses series-elastic actuation for increased safety and active compliance (self-steering). We present the design, kinematic modeling, and calibration of this system. A multi-mode real-time control architecture of the system was implemented and experimentally validated. We demonstrate the use of the robotic catheter for branch selection, insertion in an unknown channel under active compliance, and autonomous deployment within a 2D vasculature model. Furthermore, we developed algorithms for intra-operative catheter tracking and pose filtering. Methods presented in this paper make significant strides towards the future goal of enabling semi-autonomous navigation for neuroendovascular procedures.Keywords
Funding Information
- National Institutes of Health from the National Institute of Biomedical Imaging and Bioengineering (T32EB021937)
This publication has 54 references indexed in Scilit:
- Robotic-Assisted Percutaneous Coronary InterventionInterventional Cardiology Clinics, 2019
- The Steerable Microcatheter: A New Device for Selective CatheterisationCardioVascular and Interventional Radiology, 2017
- Ultrasound Imaging Velocimetry: a reviewExperiments in Fluids, 2016
- Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A ReviewAnnals of Biomedical Engineering, 2013
- Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: A prospective case control studyInternational Journal of Cardiology, 2013
- Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: A single-centre prospective studyArchives of Cardiovascular Diseases, 2013
- A novel radiofrequency ablation catheter using contact force sensing: Toccata studyHeart Rhythm, 2012
- Clinical applications of robotic technology in vascular and endovascular surgeryJournal of Vascular Surgery, 2011
- Steerable catheters in minimally invasive vascular surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2009
- Atrial Fibrillation Ablation Using a Robotic Catheter Remote Control SystemJACC, 2008