The role of ultrasound biomicroscopy in ocular trauma.
Authors:
- G K ShahGSG K Shah
- C R BaumalCBC R Baumal
- M S FinemanMFM S Fineman
- Z M CorrĕaZCZ M Corrĕa
- W E BensonWBW E Benson
- C J RapuanoCRC J Rapuano
- E J CohenECE J Cohen
- J J AugsburgerJAJ J Augsburger
- 1 January 1998
- journal article
- case report
- Vol. 96, 355-367
Abstract
To demonstrate the usefulness of ultrasound biomicroscopy (UBM) in detecting and localizing small ocular foreign bodies. This is a retrospective study of the records of 555 consecutive patients evaluated by UBM by the Visual Physiology Unit of the Wills Eye Hospital from August 1994 to November 1997. In 9 patients, a foreign body was identified. In 6 patients, the history suggested the presence of a foreign body, but one could not be detected by clinical examination. In 2 patients, the referring physicians requested UBM to determine whether or how deep a known foreign body had penetrated the globe. In 1 patient, the foreign body was not suspected clinically. In regard to other diagnostic techniques, CT failed to identify the foreign body in 1 patient. In another, contact B-scan ultrasonography failed. In a third, both CT and contact B-scan ultrasonography failed. The foreign body was intracorneal in 2 eyes, subconjunctival in 2, intrascleral in 3, and intraocular in 2. Six were nonmetallic. Two were metallic. In one case, the foreign body was lost and its composition is unknown. In 5 cases, the UBM findings altered the patient's management. UBM is a valuable adjunct in the evaluation of small, anteriorly located foreign body that may not be detectable by other methods. UBM may be especially useful for finding nonmetallic foreign bodies.Keywords
This publication has 25 references indexed in Scilit:
- A Standardized Classification of Ocular TraumaOphthalmology, 1996
- Malignant GlaucomaOphthalmology, 1994
- Clinical Use of Ultrasound BiomicroscopyOphthalmology, 1991
- Intraorbital WoodOphthalmology, 1990
- Ferrous Intraocular Foreign Bodies and Magnetic Resonance ImagingAmerican Journal of Ophthalmology, 1988
- Detection and Localization of Nonmetallic Intraocular Foreign Bodies by Magnetic Resonance ImagingArchives of Ophthalmology (1950), 1988
- Magnetic Resonance Imaging and Intraocular Foreign BodiesArchives of Ophthalmology (1950), 1987
- Limitations of Computerized Tomography in the Localization of intraocular Foreign BodiesOphthalmology, 1984
- Computed Tomography in Penetrating Wounds of the Orbit With Retained Foreign BodiesJAMA Otolaryngology–Head & Neck Surgery, 1983
- Detection of orbital foreign bodies with computed tomography: current limitsAmerican Journal of Roentgenology, 1981