A force-balanced negative feedback method for MEMS based electrochemical seismic sensor
Authors:
- 1 October 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Abstract
This paper presents a MEMS based electrochemical seismic sensor with force-balanced negative feedback where the bandwidth of the proposed device was extended from 7-20 Hz to 0.1-50 Hz. The quantified sensitivity of 3227 V/ (m/s) was 161.4 times greater than the commercial moving-coil seismic sensor in the low frequency domain. The proposed seismic sensor may be widely used as a promising seismic detecting device in the field of seismology.Keywords
This publication has 4 references indexed in Scilit:
- A MEMS Based Electrochemical Vibration Sensor for Seismic Motion MonitoringJournal of Microelectromechanical Systems, 2013
- A micro electrochemical seismic sensor based on MEMS technologiesSensors and Actuators A: Physical, 2013
- Low Frequency Electrochemical Accelerometer with Low Noise Based on MEMSKey Engineering Materials, 2012
- The Principles of the SolionPlatinum Metals Review, 1960