Evaluation of computer-aided detection (CAD) devices
Authors:
- R M Given-WilsonRGR M Given-Wilson
- 1 January 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 78 (suppl_1) , S26-S30
Abstract
We present a review of three major UK studies of computer-aided detection (CAD) for mammography. A short account of the motivation, methods and results is given for each of the three. A number of conclusions are drawn, particularly about the merits and difficulties of research in the field. The first two studies measured the impact of CAD on the sensitivity and specificity of film readers interpreting cases with known outcomes displayed on rollers with an artificially high frequency of cancers. In the first study 50 film readers each read 180 cases, including 60 cancers (40 screen-detected and 20 interval). In the second study 35 film readers viewed 120 cases including 44 cancers, of which 40 were selected to be difficult cases that CAD prompted correctly. The third study was carried out prospectively. 6111 films were independently double read by film readers who recorded a judgement before and after viewing CAD prompts. In addition to this, intraobserver measure of the impact of CAD, we compared the cancer detection rate in these cases with that in 1339 cases read over the same period without the benefit of CAD. None of the three studies showed a statistically significant effect attributable to CAD. There is evidence that a high proportion of missed cancers are prompted and that "emphasised" prompts, which have a greater positive predictive value, have a stronger impact on decision-making that other prompts.Keywords
This publication has 13 references indexed in Scilit:
- Assessing the impact of CAD on the sensitivity and specificity of film readersClinical Radiology, 2004
- Computer-aided detection in mammographyClinical Radiology, 2004
- Changes in Breast Cancer Detection and Mammography Recall Rates After the Introduction of a Computer-Aided Detection SystemJNCI: Journal of the National Cancer Institute, 2004
- An evaluation of the impact of computer-based prompts on screen readers' interpretation of mammogramsBritish Journal of Radiology, 2004
- Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammographyEuropean Journal of Radiology, 2003
- Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast CenterRadiology, 2001
- Radiologist Detection of Microcalcifications With and Without Computer-Aided Detection: A Comparative StudyClinical Radiology, 2001
- Potential Contribution of Computer-aided Detection to the Sensitivity of Screening MammographyRadiology, 2000
- Observer variability in cancer detection during routine repeat (incident) mammographic screening in a study of two versus one view mammographyJournal of Medical Screening, 1999
- Improvement in Radiologists?? Detection of Clustered Microcalcifications on MammogramsInvestigative Radiology, 1990