Preliminary research on monitoring of cerebral ischemia using electrical impedance tomography technique
Authors:
- 1 August 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 1188-1191
Abstract
More than half of the stroke patients are cause by cerebral ischemia/ hypoxia, and it is by no means an easy affairs to detect ischemic tissue when it is rescuable by drug intervention using traditional imaging technique. The purpose of this paper is to testify the feasibility of monitoring cerebral ischemia. By a newly developed high precision data acquisition system and specially configured imaging method, a series of imaging monitoring experiments were performed on 8 Chinese local rabbits, who have been induced with cortical ischemia by photochemical method. This method of induce ischemia was confirmed by histopathological examination. The imaging results show that impedance in target area increased rapidly 7–20 minutes after the beginning of the irradiation during ischemia induce process, and will still change rapidly during and after the induction of ischemia. Unexpected impedance fluctuations were also seen in 6 out of 8 animals during this process. Therefore, EIT monitoring technique proved to be a rapid and sensitive way to detect cerebral ischemia in very earlier stage.Keywords
This publication has 10 references indexed in Scilit:
- Pseudo-polar drive patterns for brain electrical impedance tomographyPhysiological Measurement, 2006
- Electrical Impedance Tomography: Methods, History and ApplicationsMedical Physics, 2005
- Cerebral impedance and neurological outcome following a mild or severe hypoxic/ischemic episode in neonatal pigletsBrain Research, 2003
- Weighted regularization in electrical impedance tomography with applications to acute cerebral strokeIEEE Transactions on Medical Imaging, 2002
- A multi-shell algorithm to reconstruct EIT images of brain functionPhysiological Measurement, 2002
- Design and performance of the UCLH Mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain functionPhysiological Measurement, 2002
- Prediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRINeurology, 1998
- Cerebral functional changes following cardiac surgery: Neuropsychological and EEG assessmentEuropean Journal of Cardio-Thoracic Surgery, 1998
- Three-dimensional electrical impedance tomographyNature, 1996
- Induction of reproducible brain infarction by photochemically initiated thrombosisAnnals of Neurology, 1985