Time‐resolving characterization of molecular weight retention changes among three synthetic high‐flux dialyzers
Authors:
- 22 February 2022
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 46 (7) , 1318-1327
Abstract
Background: Toxin removal capacity (i.e., performance) of a dialyzer is not constant but diminishes during treatment, as the adsorption of proteins to the membrane provides an additional barrier to uremic solutes. We investigated time‐resolving molecular weight retention changes among synthetic high‐flux dialyzers and compared the results with recent data from a randomized controlled trial.Methods: In plasma recirculation experiments over 240 min, sieving coefficients (SC) for β2‐microglobulin, myoglobin, and albumin were determined for the FX CorAL (Fresenius Medical Care), ELISIO (Nipro), and xevonta (B. Braun). Molecular weight retention (MWR) curves were generated and the shifts over 120 min were characterized. Effective pore radius was determined, and the predicted albumin loss was compared with clinical data.Results: SC decreased over time for all dialyzers (mean relative decrease across all dialyzers: β2‐microglobulin: 8.0% (120 min); myoglobin: 56.6% (240 min); albumin: 94.1% (240 min)). FX CorAL (7.3%, 52.6% and 91.1%) and ELISIO (7.7%, 51.0%, and 93.8%) showed a lower decrease than xevonta (9.0%, 66.2%, and 97.4%). For all dialyzers, MWR curves shifted toward lower molecular weight, with the lowest shift for FX CorAL (by 0.23 nm at SC50%, 120 min) and highest for xevonta (0.50 nm). FX CorAL had the highest slope over time and the smallest decrease in the effective pore radius (2 min: 2.31 nm, 120 min: 2.08 nm). Predicted albumin loss over 4 h was highest for xevonta (609.3 mg) and comparable between ELISIO (283.6 mg) and FX CorAL (313.3 mg).Conclusions: Substantial differences in the temporal performance profile of dialyzers exist. The present approach allows the characterization of dialyzer permeability changes over time using standard, clinically relevant protein markers.Keywords
This publication has 32 references indexed in Scilit:
- The Impact of β2-Microglobulin Clearance on the Risk Factors of Cardiovascular Disease in Hemodialysis PatientsASAIO Journal, 2010
- Loss of size selectivity of the glomerular filtration barrier in rats following laparotomy and muscle traumaAmerican Journal of Physiology-Renal Physiology, 2009
- Nanotechnological Characterization of Human Serum Albumin Adsorption on Wet Synthetic Polymer Dialysis Membrane SurfacesASAIO Journal, 2009
- Excess mortality due to interaction between protein-energy wasting, inflammation and cardiovascular disease in chronic dialysis patientsNephrology Dialysis Transplantation, 2008
- Serum β-2 Microglobulin Levels Predict Mortality in Dialysis PatientsJournal of the American Society of Nephrology, 2006
- Ficoll and dextran vs. globular proteins as probes for testing glomerular permselectivity: effects of molecular size, shape, charge, and deformabilityAmerican Journal of Physiology-Renal Physiology, 2005
- How polysulfone dialysis membranes containing polyvinylpyrrolidone achieve excellent biocompatibility?Journal of Membrane Science, 2004
- Review on uremic toxins: Classification, concentration, and interindividual variabilityKidney International, 2003
- Considerations on Developmental Aspects of Biocompatible Dialysis MembranesArtificial Organs, 1995
- Effect of Blood Contact on the Transport Properties of Hemodialysis Membranes: A Two-Layer Membrane ModelBlood Purification, 1994