Abstract
Automation of radiation biodosimetry is one of the top priority tasks considered by the Office of Science and Technology Policy and the Homeland Security Council in preparation for the nation's readiness for a possible radionuclear terrorist attack. The Center for Biophysical Assessment and Risk Management Following Irradiation, a consortium of researchers and institutions centered at the University of Rochester, has been investigating automated scoring of radiation-induced micronucleus formation in reticulocytes for high-throughput radiation biodosimetry. The collaborative project is based on a commercially-available product by Litron Laboratories in Rochester, New York. The study was designed to validate the flow-cytometry based analysis of micronucleated reticulocyte expression for radiation biodosimetry by benchmarking against the standard lymphocyte-based biodosimetry methods in a mouse model. C57B1/6 mice and C3H mice were exposed to Cs total-body radiation from 0-3 Gy. Blood samples were subsequently analyzed for CD71+ micronucleated reticulocyte and reticulocyte frequencies by flow cytometry. Results showed a linear dose-response of MN-RET up to 1 Gy for C57B1/6 and 2 Gy for C3H mice. On the other hand, robust and good dose-response curves were obtained with lymphocyte-based dicentric assay and cytokinesis-block micronucleus assay up to 3 Gy. High-throughput, automated analyses of micronucleated reticulocytes is a sensitive and reproducible method for detecting recent radiation exposure. In mice, the dose range of detection is useful up to 1 Gy (C57Bl/6) and 2 Gy (C3H) but not reliable beyond these dose limits. The utilization of this automated analysis for human radiation biodosimetry is currently under investigation.Keywords
This publication has 30 references indexed in Scilit:
- Automated image analysis of cytokinesis-blocked micronuclei: an adapted protocol and a validated scoring procedure for biomonitoringMutagenesis, 2008
- Reticulocyte and micronucleated reticulocyte responses to gamma irradiation: dose–response and time-course profiles measured by flow cytometryMutation Research - Genetic Toxicology and Environmental Mutagenesis, 2007
- Automated human blood micronucleated reticulocyte measurements for rapid assessment of chromosomal damageMutation Research - Genetic Toxicology and Environmental Mutagenesis, 2007
- Three‐color labeling method for flow cytometric measurement of cytogenetic damage in rodent and human bloodEnvironmental and Molecular Mutagenesis, 2004
- Micronucleated CD71-positive reticulocytes: a blood-based endpoint of cytogenetic damage in humansMutation Research - Genetic Toxicology and Environmental Mutagenesis, 2003
- Human cytogenetic biomonitoring using flow-cytometric analysis of micronuclei in transferrin-positive immature peripheral blood reticulocytesEnvironmental and Molecular Mutagenesis, 2000
- Simple and reliable enumeration of micronucleated reticulocytes with a single-laser flow cytometerMutation Research/Genetic Toxicology, 1996
- The time-course of micronucleated polychromatic erythrocytes in mouse bone marrow and peripheral bloodMutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, 1996
- Technical report Automated scoring of micronuclei in binucleated human lymphocytesInternational Journal of Radiation Biology, 1996
- Chromosome aberrations and radiation-induced cell deathMutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, 1973