A piezoresistive tactile sensor for tissue characterization during catheter‐based cardiac surgery
- 4 October 2011
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 7 (4) , 431-440
Abstract
Background Currently, most of mitral valve annuloplasty surgeries are performed by using open heart surgery. However, if such operation would be performed by using minimally invasive surgery via catheter-based techniques (CBT), it offers various advantages for both surgeons and patients. Methods Two piezoresistive force sensors are used in the structure of the tactile sensor, which can easily be miniaturized and integrated into surgical catheters. The tactile sensor was fabricated and tested to characterize different elastomers, as the phantom of cardiac tissues. Based on a developed finite element analysis (FEA) of the elastomers, the interaction between the sensor and those materials were modelled to validate the output of the sensor. Results The results of the mechanical and psychophysical tests confirm the capability of the proposed sensor to measure the relative hardness/softness of different soft tissues. Conclusions The proposed tactile sensor will help surgeons to characterize different types of cardiac tissues and would facilitate the use of CBT to perform mitral valve annuloplasty. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 28 references indexed in Scilit:
- 3D Graphical Rendering of Localized Lumps and Arteries for Robotic Assisted MISJournal of Medical Devices, 2011
- New tactile sensing system for minimally invasive surgical tumour localizationThe International Journal of Medical Robotics and Computer Assisted Surgery, 2010
- MEMS Endoscopic Tactile Sensor: TowardIn-SituandIn-VivoTissue Softness CharacterizationIEEE Sensors Journal, 2009
- Robotic Force Stabilization for Beating Heart Intracardiac Surgery2009
- An integrated pneumatic tactile feedback actuator array for robotic surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008
- A multifunctional PVDF-based tactile sensor for minimally invasive surgerySmart Materials and Structures, 2007
- Robotic technology in surgery: Past, present, and futureThe American Journal of Surgery, 2004
- Slip and damage properties of jaws of laparoscopic graspersSurgical Endoscopy, 2004
- Natural StrainJournal of Engineering Materials and Technology, 1995