Assay of Olanzapine in Human Plasma by a Rapid and Sensitive Gas Chromatography-Nitrogen Phosphorus Selective Detection (GC-NPD) Method
Author:
- 1 August 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 27 (4) , 463-468
Abstract
A gas chromatography-nitrogen phosphorus selective detection (GC-NPD) method with a simple 1-step sample preparation was developed for the assay of the antipsychotic drug olanzapine in plasma. Within a time of analysis of 7 minutes, an HP-5 fused-silica capillary (25 m x 0.2 mm ID, 0.33-microm film thickness, 0.7 mL N2 as carrier gas) provided selectivity with respect to about 30 psychotropic drugs and the internal standard ethylolanzapine. Calibration was linear between 1 and 50 ng/mL and crossed the origin (LOD = 0.3 ng/mL). Intraday precision was 6.7%, 2.7%, and 1.4% at plasma concentrations of 1, 5, and 50 ng/mL, respectively. Interday precision was 4.6% at 20 ng/mL. Accuracy in commercial interlaboratory tests was 108.7% and 88.5%. The method also provided good accuracy in comparison with an HPLC method for patient samples (slope 1.003, r = 0.953) and spiked samples (slope 0.881, r = 0.998). GC-NPD with a simple sample preparation is regarded as an alternative for the assay of olanzapine plasma concentrations in therapeutic drug monitoring (TDM) and in pharmacokinetic studies. Smokers and patients taking concomitant carbamazepine had reduced plasma concentrations of olanzapine. Women and patients older than 60 years had increased plasma olanzapine concentrations.Keywords
This publication has 21 references indexed in Scilit:
- Therapeutic Monitoring of Psychotropic DrugsTherapeutic Drug Monitoring, 2004
- Olanzapine Plasma Concentrations and Clinical Response: Acute Phase Results of the North American Olanzapine TrialJournal of Clinical Psychopharmacology, 2001
- OlanzapineDrugs, 2001
- A sensitive high-performance liquid chromatographic method using electrochemical detection for the analysis of olanzapine and desmethylolanzapine in plasma of schizophrenic patients using a new solid-phase extraction procedureJournal of Chromatography B: Biomedical Sciences and Applications, 2000
- Olanzapine Concentrations in Clinical Serum and Postmortem Blood Specimens—When Does Therapeutic Become Toxic?Journal of Forensic Sciences, 2000
- Determination of olanzapine in human plasma and serum by liquid chromatography/tandem mass spectrometryJournal of Mass Spectrometry, 1998
- Determination of olanzapine in serum by high-performance liquid chromatography using ultraviolet detection considering the easy oxidability of the compound and the presence of other psychotropic drugsJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- Olanzapine Plasma Concentrations and Clinical Response in Acutely Ill Schizophrenic PatientsJournal of Clinical Psychopharmacology, 1997
- Plasma Level Monitoring of Olanzapine in Patients With SchizophreniaTherapeutic Drug Monitoring, 1997
- Analysis of olanzapine in human plasma utilizing reversed-phase high-performance liquid chromatography with electrochemical detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1995