Simulation of scintillation light output in LYSO scintillators through a full factorial design
- 4 January 2017
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (2) , 669-683
Abstract
Individually coupled scintillation detectors used in positron emission tomography (PET) imaging suffer from important signal losses due to the suboptimal light collection from crystals. As only a fraction of the light is generally extracted from long and thin scintillators, it is important to identify and understand the predominant causes of signal loss in order to eventually recover it. This simulation study investigates the multiple factors affecting the light transport in high-aspect ratio LYSO scintillators wrapped in specular reflectors through a full factorial design. By exploring various combinations of crystal geometry, readout conditions and wrapping conditions, it was found that an optimum light output can only be achieved through a careful selection of highly reflective material along with high-transmittance optical adhesive used to bond the reflector. Decreasing the adhesive thickness was also found to have a positive outcome in most explored configurations, however to a much lesser extent. Suboptimal reflectivity and adhesive transmittance also lead to an asymmetric light output distribution dependent on the depth of interaction of the radiation, potentially degrading energy resolution. By identifying the factors causing the most significant scintillation light losses through a factorial design, the most promising detector configurations have been identified in the quest for optimal light collection from scintillators.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 37 references indexed in Scilit:
- Preliminary performance characterization of DbPET2.1, a PET scanner dedicated to the imaging of the breast and extremitiesBiomedical Physics & Engineering Express, 2015
- LabPET II, an APD-based Detector Module with PET and Counting CT Imaging CapabilitiesIEEE Transactions on Nuclear Science, 2015
- Simulation study of PET detector limitations using continuous crystalsPhysics in Medicine & Biology, 2015
- Performance evaluation of a prototype Positron Emission Tomography scanner using Digital Photon Counters (DPC)2012
- A comprehensive & systematic study of coincidence time resolution and light yield using scintillators of different size, wrapping and doping2011
- Development of a 64-channel APD detector module with individual pixel readout for submillimetre spatial resolution in PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- GEANT4 studies on the propagation and detection of scintillation light in long thin YAP crystalsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Detection of photons generated in PbW04 scintillator crystalsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998