Relation between size of optic disc and thickness of retinal nerve fibre layer in normal subjects
Authors:
- Motohiro ShirakashiMSMotohiro Shirakashi
- Haruki AbeHAHaruki Abe
Open Access
- 1 November 1998
- journal article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 82 (11) , 1242-1245
Abstract
AIMS To evaluate the relation between the optic disc size and the thickness of the peripapillary retinal nerve fibre layer (RNFL) in normal Japanese subjects by means of scanning laser polarimetry. METHODS Scanning laser polarimetry was performed in 60 normal subjects. One eye of each subject was randomly selected for study. Using a scanning laser polarimeter, the integral of RNFL thickness was measured totally and regionally within a circular band located 1.75 disc diameters from the centre of the optic disc. The correlation between the optic disc size and the integral of RNFL thickness was examined. RESULTS The optic disc size showed a significant correlation with the integral of RNFL thickness (R = 0.497, p R = −0.274, p = 0.034). CONCLUSIONS The cross sectional area occupied by the RNF, measured by scanning laser polarimetry increased significantly with an increase in optic disc size while the ratio of inferior to total cross sectional area decreased significantly. These facts should be considered when one evaluates the RNFL thickness in patients with progressive optic neuropathies such as glaucoma.Keywords
This publication has 19 references indexed in Scilit:
- Nerve Fiber Layer Measurements With Scanning Laser Polarimetry in Ocular HypertensionArchives of Ophthalmology (1950), 1997
- Correction of optic disc measurements on fundus photographsGraefe's Archive for Clinical and Experimental Ophthalmology, 1992
- Larger Optic Nerve Heads Have More Nerve Fibers in Normal Monkey EyesArchives of Ophthalmology (1950), 1991
- Relation between Optic Nerve Axon Number and Axon Diameter to Scleral Canal AreaOphthalmology, 1991
- Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer ThicknessArchives of Ophthalmology (1950), 1990
- Racial Differences in Optic Nerve Head ParametersArchives of Ophthalmology (1950), 1989
- Human fetal optic nerve: Overproduction and elimination of retinal axons during developmentJournal of Comparative Neurology, 1985
- Overproduction and Elimination of Retinal Axons in the Fetal Rhesus MonkeyScience, 1983
- Quantitative Studies of Retinal Nerve Fiber Layer DefectsArchives of Ophthalmology (1950), 1982
- Thickness of the Retinal Nerve Fiber Layer in Primate EyesArchives of Ophthalmology (1950), 1980