Abstract
OBJECTIVE. The objective of our study was to investigate whether an increasing number of computer-aided detection (CAD) false-positives decreases reader sensitivity, specificity, and confidence for nonexpert readers of CT colonography (CTC).MATERIALS AND METHODS. Fifty CTC data sets (29 men; mean age, 65 years), 25 of which contained 35 polyps ≥ 5 mm, were selected in which CAD had 100% polyp sensitivity at two sphericity settings (0 and 75) but differed in the number of false-positives. The data sets were read by five readers twice: once at each sphericity setting. Sensitivity, specificity, report time, and confidence before and after second-read CAD were compared using the paired exact and Student's t test, respectively. Receiver operating characteristic (ROC) curves were generated using reader confidence (1–100) in correct case classification (normal or abnormal).RESULTS. CAD generated a mean of 42 (range, 3–118) and 15 (range, 1–36) false-positives at a sphericity of 0 and 75, respectively. CAD at bot...

This publication has 24 references indexed in Scilit: