Influence of Computer-Aided Detection False-Positives on Reader Performance and Diagnostic Confidence for CT Colonography
- 1 June 2009
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (6) , 1682-1689
Abstract
OBJECTIVE. The objective of our study was to investigate whether an increasing number of computer-aided detection (CAD) false-positives decreases reader sensitivity, specificity, and confidence for nonexpert readers of CT colonography (CTC).MATERIALS AND METHODS. Fifty CTC data sets (29 men; mean age, 65 years), 25 of which contained 35 polyps ≥ 5 mm, were selected in which CAD had 100% polyp sensitivity at two sphericity settings (0 and 75) but differed in the number of false-positives. The data sets were read by five readers twice: once at each sphericity setting. Sensitivity, specificity, report time, and confidence before and after second-read CAD were compared using the paired exact and Student's t test, respectively. Receiver operating characteristic (ROC) curves were generated using reader confidence (1–100) in correct case classification (normal or abnormal).RESULTS. CAD generated a mean of 42 (range, 3–118) and 15 (range, 1–36) false-positives at a sphericity of 0 and 75, respectively. CAD at bot...Keywords
This publication has 24 references indexed in Scilit:
- CT Colonography and Computer-aided Detection: Effect of False-Positive Results on Reader Specificity and Reading Efficiency in a Low-Prevalence Screening PopulationRadiology, 2008
- Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonographyMedical Physics, 2008
- CT Colonography with Computer-aided Detection as a Second Reader: Observer Performance StudyRadiology, 2008
- Computer-aided Detection of Colorectal Polyps: Can It Improve Sensitivity of Less-Experienced Readers? Preliminary FindingsRadiology, 2007
- Effect of computer-aided detection as a second reader in multidetector-row CT colonographyEuropean Radiology, 2007
- Computer assisted detection software for CT colonography: effect of sphericity filter on performance characteristics for patients with and without fecal taggingEuropean Radiology, 2006
- Computer-assisted detection for CT colonography: external validationClinical Radiology, 2006
- Computer-Assisted Reader Software Versus Expert Reviewers for Polyp Detection on CT ColonographyAmerican Journal of Roentgenology, 2006
- Computer-Aided diagnosis for CT colonographySeminars in Ultrasound, CT and MRI, 2004
- CAD techniques, challenges, andcontroversies in computed tomographic colonographyAbdominal Radiology, 2004