Bearing capacity of two interfering footings
- 3 May 2007
- journal article
- research article
- Published by Wiley in International Journal for Numerical and Analytical Methods in Geomechanics
- Vol. 32 (3) , 251-264
Abstract
By using an upper bound limit analysis in conjunction with finite elements and linear programming, the ultimate bearing capacity of two interfering rough strip footings, resting on a cohesionless medium, was computed. Along all the interfaces of the chosen triangular elements, velocity discontinuities were employed. The plastic strains were incorporated using an associated flow rule. For different clear spacing (S) between the two footings, the efficiency factor (ξγ) was determined, where ξγ is defined as the ratio of the failure load for a strip footing of given width in the presence of the other footing to that of a single isolated strip footing having the same width. The value of ξγ at S/B = 0 becomes equal to 2.0, and the maximum ξγ occurs at S/B = Scr/B. For S/B⩽Scr/B, the ultimate failure load for a footing becomes almost half that of an isolated footing having width (2B + S), and the soil mass below and in between the two footings deforms mainly in the downward direction. In contrast, for S/B>Scr/B, ground heave was noticed along both the sides of the footing. As compared to the available theories, the analysis provides generally lower values of ξγ for S/B>Scr/B. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 12 references indexed in Scilit:
- Ultimate Bearing Capacity of Two Interfering Rough Strip FootingsInternational Journal of Geomechanics, 2007
- A new discontinuous upper bound limit analysis formulationInternational Journal for Numerical Methods in Engineering, 2005
- Numerical limit analysis solutions for the bearing capacity factor NγInternational Journal of Solids and Structures, 2005
- Closely Spaced Footings on Geogrid-Reinforced SandJournal of Geotechnical and Geoenvironmental Engineering, 2003
- Calculations of Bearing Capacity Factor Nγ Using Numerical Limit AnalysesJournal of Geotechnical and Geoenvironmental Engineering, 2003
- Upper bound limit analysis using discontinuous velocity fieldsComputer Methods in Applied Mechanics and Engineering, 1995
- Bearing capacity of three closely-spaced footings on sandGéotechnique, 1984
- Bearing Capacity of Two Closely-Spaced Shallow Foundations on SandSoils and Foundations, 1983
- Finite element method and limit analysis theory for soil mechanics problemsComputer Methods in Applied Mechanics and Engineering, 1980
- Interference Between Foundations, with Special Reference to Surface Footings in SandGéotechnique, 1962