An improved real-time detection algorithm based on frequency interpolation
Open Access
- 25 July 2023
- journal article
- research article
- Published by Springer Nature in EURASIP Journal on Wireless Communications and Networking
- Vol. 2023 (1) , 1-13
Abstract
Real-time monitoring of heart rate (HR), i.e., extraction of heart rate variability (HRV), plays an important role in diagnosis and prevention of cardiovascular diseases. Compared with traditional contact monitoring devices, the use of continuous wave (CW) Doppler radar to monitor HRV does not require contact and is not sensitive to light and temperature, which makes it more and more popular. To monitor the HRV based on CW Doppler radar, the time window must be shortened to less than 5 s, which will lead to the spectrum leakage and degrade the measurement accuracy of HRV. To solve this problem, a custom CW Doppler radar has been developed in an integrated fashion on a single PCB, whose transmitting frequency and power of the radar are 24 GHz and 3 dBm, respectively. Furthermore, four frequency interpolation algorithms are introduced to compare their extraction accuracy. Experiments are performed on three subjects, and results show that the Quinn algorithm can obtain best HRV extraction results compared with other algorithms. Specially, the average HRV extraction error is 3.61% using the Quinn algorithm.Keywords
All Related Versions
Funding Information
- Scientific Research Project of Tianjin Municipal Education Commission (2021KJ016)
This publication has 37 references indexed in Scilit:
- Wristband-Type Driver Vigilance Monitoring System Using SmartwatchIEEE Sensors Journal, 2015
- Benefits of Coherent Low-IF for Vital Signs Monitoring Using Doppler RadarIEEE Transactions on Microwave Theory and Techniques, 2014
- Anxiety Disorders are Associated with Reduced Heart Rate Variability: A Meta-AnalysisFrontiers in Psychiatry, 2014
- Use of Heart Rate Variability in Monitoring Stress and Recovery in Judo AthletesJournal of Strength & Conditioning Research, 2014
- Respiration harmonics cancellation for Accurate Heart Rate measurement in non-contact vital sign detection2013
- A real-time heart rate analysis for a remote millimeter wave I-Q sensorIEEE Transactions on Biomedical Engineering, 2011
- Range Correlation and$ I/ Q$Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary MonitoringIEEE Transactions on Microwave Theory and Techniques, 2004
- Fast nearly ML estimation of the parameters of real or complex single tones or resolved multiple tonesIEEE Transactions on Signal Processing, 1998
- Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitoredMedical & Biological Engineering & Computing, 1997
- Estimating frequency by interpolation using Fourier coefficientsIEEE Transactions on Signal Processing, 1994