Opening Injection Pressure Is Higher in Intraneural Compared With Perineural Injections During Simulated Nerve Blocks of the Lower Limb in Fresh Human Cadavers
Authors:
- Kris VermeylenKVKris Vermeylen
- Marlies HermansMHMarlies Hermans
- Filiep SoetensFSFiliep Soetens
- Evie VereeckeEVEvie Vereecke
- Thorsten SteinfeldtTSThorsten Steinfeldt
- Gerbrand GroenGGGerbrand Groen
- Admir HadzicAHAdmir Hadzic
- Marc Van de VeldeMVMarc Van de Velde
- 1 January 2017
- journal article
- research article
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 42 (3) , 362-367
Abstract
BACKGROUND AND OBJECTIVES Needle-induced nerve trauma and intraneural injection can lead to neurologic injury during peripheral nerve blocks. In this study, we assessed the utility of opening injection pressure (OIP), time to OIP, and rate of rise to OIP in detecting needle-nerve contact and intraneural injection. METHODS Five common ultrasound-guided blocks of the femoral, saphenous, subgluteal sciatic, tibial, and common peroneal nerves were simulated in 10 fresh cadavers. Opening injection pressure was defined as peak psi in the 60-second interval during which the injection is initiated. Pressure-time curves were constructed separately for intraneural and perineural injections for each of the 5 nerves studied. RESULTS Opening injection pressure was higher for intraneural than for perineural injections (P < 0.001), ranging from 21.5 psi (1111.9 mm Hg) to 25.8 psi (1334.2 mm Hg) for intraneural injections and from 3.8 psi (196.5 mm Hg) to 6.1 psi (315.5 mm Hg) for perineural injections. Time to OIP tended to be shorter for intraneural than for perineural injections, particularly for the subgluteal sciatic, tibial, and common peroneal nerves. Curves of intraneural injections had steep slopes with high peaks; curves of perineural injections had low slopes followed by plateaus. Rise to OIP was greater for intraneural than for perineural injections. CONCLUSIONS In our fresh human cadaver model, OIP detected intraneural needle placement. Monitoring of OIP could be useful in detecting and/or preventing intraneural injection during nerve blocks in the clinical setting.Keywords
This publication has 24 references indexed in Scilit:
- Needle-nerve proximity during peripheral nerve blocks – Where is the right target and how can we get there?Revista Española de Anestesiología y Reanimación, 2015
- Peripheral Nerve Injury After Local Anesthetic InjectionAnesthesia & Analgesia, 2013
- Incidence of Local Anesthetic Systemic Toxicity and Postoperative Neurologic Symptoms Associated With 12,668 Ultrasound-Guided Nerve BlocksRegional Anesthesia & Pain Medicine, 2012
- Brachial Plexus Root Injection in a Human Cadaver ModelRegional Anesthesia & Pain Medicine, 2012
- Forced Needle Advancement During Needle-Nerve Contact in a Porcine ModelAnesthesia & Analgesia, 2011
- Complications Associated With Peripheral Nerve BlocksInternational Anesthesiology Clinics, 2011
- Complications of peripheral nerve blocksBritish Journal of Anaesthesia, 2010
- Functional Deficits After Intraneural Injection During Interscalene BlockRegional Anesthesia & Pain Medicine, 2010
- Preliminary Results of the Australasian Regional Anaesthesia CollaborationRegional Anesthesia & Pain Medicine, 2009
- Pathophysiology of Peripheral Nerve Injury During Regional AnesthesiaRegional Anesthesia & Pain Medicine, 2008