A blood-mimicking fluid with cholesterol as scatter particles for wall-less carotid artery phantom applications
Open Access
- 16 August 2021
- journal article
- research article
- Published by Medical Communications Sp. z.o.o. in Journal of Ultrasonography
- Vol. 21 (86) , e219-e224
Abstract
Aim of the study: At present, there are few scatter particles used in preparing blood-mimicking fluids, such as nylon, sephadex, polystyrene microsphere, and poly(4-methystyrene). In this study, we present cholesterol as a new scatter particle for blood-mimicking fluid preparation. Materials and methods: The procedure for the preparation of the proposed blood-mimicking fluid involved the use of propylene glycol, D(+)-Glucose and distilled water to form a ternary mixture fluid, with cholesterol used as scatter particles. Polyethylene glycol was first used as part of the mixture fluid but the acoustic and physical properties were not suitable, leading to its replacement with D(+)-Glucose, which is soluble in water and has a higher density. A common carotid artery wall-less phantom was also produced to assess the flow properties. Results: The prepared blood-mimicking fluid with new scatter particles has a density of 1.067 g/cm3, viscosity of 4.1 mPa.s, speed of sound 1600 m/s, and attenuation of 0.192 dB/cm at 5 MHz frequency. Peak systolic velocity, end diastolic velocity and mean velocity measurements were gotten to be 40.2 ± 2.4 cm/s, 9.9 ± 1.4 cm/s, and 24.0 ± 1.8 cm/s, respectively. Conclusion: Based on the results obtained, the blood-mimicking fluid was found suitable for ultrasound applications in carotid artery wall-less phantoms because of its good acoustic and physical properties.Keywords
This publication has 16 references indexed in Scilit:
- An ideal blood mimicking fluid for doppler ultrasound phantomsJournal of Medical Physics, 2006
- Application of a new blood-mimicking fluid in a flow Doppler test objectEuropean Journal of Ultrasound, 1999
- A wall-less vessel phantom for Doppler ultrasound studiesUltrasound in Medicine & Biology, 1995
- Computer-controlled positive displacement pump for physiological flow simulationMedical & Biological Engineering & Computing, 1991
- Towards an ideal blood analogue for Doppler ultrasound phantomsPhysics in Medicine & Biology, 1991
- Assurance of consistent peak-velocity measurements with a variety of duplex Doppler instruments.Radiology, 1990
- A comparison of the doppler spectra from human blood and artificial blood used in a flow phantomUltrasound in Medicine & Biology, 1990
- A computer controlled flow phantom for generation of physiological Doppler waveformsPhysics in Medicine & Biology, 1989
- An in vitro model and its application for the study of carotid doppler spectral broadeningUltrasound in Medicine & Biology, 1983
- A proposed standard target for ultrasound doppler gain calibrationUltrasound in Medicine & Biology, 1981