Study of nickel levels in patients with atrial septal defect undergoing amplatzer device closure
Open Access
- 1 January 2018
- journal article
- research article
- Published by Medknow in Heart Views
- Vol. 19 (3) , 85-87
Abstract
Transcatheter closure of atrial septal defects (ASDs) using nickel titanium Naval Ordnance Laboratory (Nitinol)-containing devices (Amplatzer, AGA Medical, Golden Valley, Minnetosa) is being widely practiced. Controversies still exist regarding the release of nickel from these devices and the allergy and other ill effects of nickel and also the duration of antiplatelet therapy to aid endothelization of the device. Objective: To study the nickel levels in patients who underwent ASD closure with platinum-coated Nitinol-containing Amplatzer septal occluder. Methodology: A prospective study was conducted on 25 patients, between 6 years and 40 years of age who underwent ASD closure with Amplatzer septal occlude sizes ranging from 12 to 36 mm from January 2009 to January 2010. Blood nickel levels were estimated using atomic absorption photometry before and 24 h after the procedure and later at 1 month, 3 months, and 6 months postprocedure. A value of <2 mcg/dl was considered to be normal. Statistical analysis was performed by the use of the Wilcoxon test. Results: The blood nickel levels at mean baseline, 24 h, 1 month, 3 months, and 6 months postprocedure were 1.05, 1.39, 0.98, 0.79, and 0.74 (mcg/dl), respectively. Conclusions: Percutaneous ASD closure using Nitinol devices can be carried out safely without any significant ill effects related to nickel release.Keywords
This publication has 7 references indexed in Scilit:
- Severe Allergic Dermatitis After Closure of Foramen Ovale With Amplatzer OccluderThe Annals of Thoracic Surgery, 2013
- Cutaneous and Systemic Hypersensitivity Reactions to Metallic ImplantsDermatitis®, 2011
- Self-expanding platinum-coated nitinol devices for transcatheter closure of atrial septal defect: prevention of nickel release.2008
- Adverse Events Associated With Nickel Allergy in Patients Undergoing Percutaneous Atrial Septal Defect or Patent Foramen Ovale ClosureJACC, 2006
- Nickel release, a possible indicator for the duration of antiplatelet treatment, from a nickel cardiac device in vivo: a study in patients with atrial septal defects implanted with an Amplatzer occlInt. Journal of Clinical Pharmacology and Therapeutics, 2006
- Nickel release after implantation of the Amplatzer occluderAmerican Heart Journal, 2003
- Corrosive behaviour of Amplatzer® devices in experimental and biological environmentsCardiology in the Young, 2002