Primary Hybrid Total Hip Replacement, Performed with Insertion of the Acetabular Component without Cement and a Precoat Femoral Component with Cement. An Average Ten-Year Follow-up Study*
Authors:
- William H. HarrisWHWilliam H. Harris
- 1 February 1999
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 81 (2) , 247-255
Abstract
E proximal third, was inserted with contemporary cementing techniques (that is, use of a femoral medullary plug, a cement gun, and centrifugation and pressurization of the cement). Fifteen patients (fifteen hips) died before a minimum duration of follow-up of seven years, four patients (four hips) were too ill for a detailed follow-up examination at the time of the study, and two patients (two hips) refused to be evaluated at the time of the latest follow-up. None of these twenty-one hips had had a revision or a reoperation at the time of the latest follow-up. Eighty-six patients (100 hips) were available for clinical follow-up at an average of 120 months (range, eighty-four to 153 months) and for radiographic follow-up at an average of 118 months (range, eighty-four to 153 months). The average age of the patients at the time of the index arthroplasty was sixty-five years (range, forty-five to eighty-seven years). Three acetabular components were revised because of dissociation of the liner in association with a fracture of a locking tine. One well fixed acetabular component was revised because of pelvic osteolysis, and the femoral stem in the same patient was revised because of aseptic loosening.None of the ninety-six remaining acetabular components migrated, was classified as radiographically loose, or was revised because of aseptic loosening. Osteolytic lesions were identified adjacent to five acetabular components, and one of them was treated with bone-grafting around the well fixed acetabular shell. Two hips had a continuous radiolucent line at the interface between the acetabular implant and the bone.Three femoral stems had evidence of radiographic debonding (a radiolucent line that was one millimeter wide or less between the cement and the prosthesis), and they were classified as radiographically loose despite excellent clinical results. Seven hips had osteolytic areas located in the proximal aspect of the most proximal zones of Gruen et al., and five had small osteolytic regions in more distal areas.The Harris hip score for the eighty-two patients (ninety-six hips) who did not have a revision improved from 48 points (range, 22 to 70 points) preoperatively to 92 points (range, 53 to 100 points) at the most recent follow-up examination. Eighty-one patients had no, slight, or mild pain in the hip, and they were satisfied with the clinical result. In the present study, the hybrid total hip replacement with use of the Harris-Galante acetabular component and the Precoat femoral stem continued to provide an excellent result for most patients at an average of approximately ten years after the operation....Keywords
This publication has 38 references indexed in Scilit:
- Hybrid Total Hip ReplacementClinical Orthopaedics and Related Research, 1996
- Hybrid Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- Hybrid Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1996
- The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. A retrospective matched-pair series.Journal of Bone and Joint Surgery, 1994
- Severe polyethylene wear in total hip arthroplastyThe Journal of Arthroplasty, 1994
- Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1992
- A New Approach to Total Hip Replacement Without Osteotomy of the Greater TrochanterClinical Orthopaedics and Related Research, 1975
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958