Distal Biceps Tendon Repair
Authors:
- 1 June 2006
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 34 (6) , 968-974
Abstract
Background: A variety of techniques have been described for distal biceps tendon reattachment—bone tunnel with transosseous sutures, suture anchors, and interference screw techniques. Hypothesis: There will be no significant difference between the mean failure strength, maximum strength, and stiffness of the intact specimen and repair techniques tested: bone tunnel with transosseous sutures and interference screw. Study Design: Controlled laboratory study. Methods: Nine matched pairs of fresh-frozen human cadaveric elbows were prepared. The intact tendon was pulled from the radial tuberosity; the right and left elbows were randomized to bone tunnels with transosseous sutures or interference screw repair techniques. The repaired specimens were pulled using the same regimen for the intact tendon. Failure strength, maximum strength, and stiffness were measured and compared. Results: The mean failure strength, maximum strength, and stiffness of intact tendons were 204.3 ± 76.9 N, 221.7 ± 65.9 N, and 30.1 ± 12.4 N/mm, respectively; for the interference screw specimens, 178.0 ± 54.5 N, 192.1 ± 53.1 N, and 30.4 ± 9.5 N/mm, respectively; and for the bone tunnel specimens, 124.9 ± 22.8 N, 206.6 ± 49.8 N, and 15.9 ± 5.6 N/mm, respectively. There were no significant differences between measures in the intact and interference screw specimens. Mean failure strength and stiffness of the bone tunnel specimens were significantly lower than those of the intact and interference screw specimens; there was no significant difference between the maximum strengths of the treatments. Interference screw failure occurred abruptly with little plastic deformation in nearly all specimens with the tendon and screw pulling out as a unit, often involving fracture of the radial wall. Two of the bone tunnels failed at the bony bridge; the remainder lost bone-tendon contact as the distal tendon was shredded by the suture. Conclusion: The results suggest interference screw fixation repair is nearly as strong and stiff as the intact tendon and stronger than the bone tunnel repair technique. Clinical Relevance: The interference screw provides better stiffness and failure strength compared with the bone tunnel technique for distal biceps tendon repair. Given the superior mechanical properties, the interference screw technique is recommended as the treatment of choice for biceps tendon rupture repair.Keywords
This publication has 29 references indexed in Scilit:
- Repair of Distal Biceps Tendon Ruptures Using a Suture Anchor and an Anterior ApproachJournal of Hand Surgery (European Volume), 2004
- A New TechniqueThe American Journal of Sports Medicine, 2004
- EndoButton-assisted repair of distal biceps tendon rupturesJournal of Shoulder and Elbow Surgery, 2003
- Distal biceps tendon repair: Comparison of surgical techniquesThe Journal of Hand Surgery, 2003
- Single incision technique using an interference screw for the repair of distal biceps tendon rupturesOperative Techniques in Sports Medicine, 2003
- A simplified method for repair of distal biceps tendon rupturesJournal of Shoulder and Elbow Surgery, 2000
- Repair of distal biceps tendon ruptures in athletesThe American Journal of Sports Medicine, 1993
- Repair of the Ruptured Distal Tendon of the Biceps BrachiiJournal of Hand Surgery (European Volume), 1992
- Proximal Radioulnar Synostosis After Repair of Distal Biceps Brachii Rupture by the Two-Incision TechniqueClinical Orthopaedics and Related Research, 1990
- Distal biceps brachii tendon avulsionThe American Journal of Sports Medicine, 1986