Non-invasive pulse arrival time is associated with cardiac index in pediatric heart transplant patients with normal ejection fraction
Open Access
- 1 July 2024
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (7) , 07NT01
Abstract
Objective. Cardiac Index (CI) is a key physiologic parameter to ensure end organ perfusion in the pediatric intensive care unit (PICU). Determination of CI requires invasive cardiac measurements and is not routinely done at the PICU bedside. To date, there is no gold standard non-invasive means to determine CI. This study aims to use a novel non-invasive methodology, based on routine continuous physiologic data, called Pulse Arrival Time (PAT) as a surrogate for CI in patients with normal Ejection Fraction (EF). Approach. Electrocardiogram (ECG) and photoplethysmogram (PPG) signals were collected from beside monitors at a sampling frequency of 250 samples per second. Continuous PAT, derived from the ECG and PPG waveforms was averaged per patient. Pearson’s correlation coefficient was calculated between PAT and CI, PAT and heart rate (HR), and PAT and EF. Main Results. Twenty patients underwent right heart cardiac catheterization. The mean age of patients was 11.7 ± 5.4 years old, ranging from 11 months old to 19 years old, the median age was 13.4 years old. HR in this cohort was 93.8 ± 17.0 beats per minute. The average EF was 54.4 ± 9.6%. The average CI was 3.51 ± 0.72 l min−1 m−2, with ranging from 2.6 to 4.77 l min−1 m−2. The average PAT was 0.31 ± 0.12 s. Pearson correlation analysis showed a positive correlation between PAT and CI (0.57, p < 0.01). Pearson correlation between HR and CI, and correlation between EF and CI was 0.22 (p = 0.35) and 0.03 (p = 0.23) respectively. The correlation between PAT, when indexed by HR (i.e. PAT × HR), and CI minimally improved to 0.58 (p < 0.01). Significance. This pilot study demonstrates that PAT may serve as a valuable surrogate marker for CI at the bedside, as a non-invasive and continuous modality in the PICU. The use of PAT in clinical practice remains to be thoroughly investigated.Keywords
Funding Information
- National Institutes of Health (1R01NS129760)
- American Heart Association (20POST35210653)
This publication has 45 references indexed in Scilit:
- Clinical significance of Lactate in acute cardiac patientsWorld Journal of Cardiology, 2015
- A new predictive equation for oxygen consumption in children and adults with congenital and acquired heart diseaseHeart, 2014
- Correlation of left ventricular systolic dysfunction determined by low ejection fraction and 30-day mortality in patients with severe sepsis and septic shock: A systematic review and meta-analysisJournal of Critical Care, 2014
- Improved Interobserver Variability and Accuracy of Echocardiographic Visual Left Ventricular Ejection Fraction Assessment through a Self-Directed Learning Program Using Cardiac Magnetic Resonance ImagesJournal of the American Society of Echocardiography, 2013
- Evaluation of the estimated continuous cardiac output monitoring system in adults and children undergoing kidney transplant surgery: a pilot studyJournal of Clinical Monitoring and Computing, 2013
- Change in regional (somatic) near-infrared spectroscopy is not a useful indictor of clinically detectable low cardiac output in children after surgery for congenital heart defectsPediatric Critical Care Medicine, 2012
- Clinical assessment of hemodynamically unstable patientsCurrent Opinion in Critical Care, 2009
- Chemotherapy Induced Cardiomyopathy: Pathogenesis, Monitoring and ManagementJournal of Clinical Medicine Research, 2009
- Does Central Venous Pressure Predict Fluid Responsiveness?*: A Systematic Review of the Literature and the Tale of Seven MaresChest, 2008