Late contained aortic root rupture and ventricular septal defect after transcatheter aortic valve implantation
Authors:
- 4 May 2012
- journal article
- case report
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 81 (1) , E72-E75
Abstract
Transcatheter aortic valve implantation (TAVI) is a highly specialized technique offering a new therapeutic option to patients at high risk for conventional surgery. However, despite continuous improvements in operators' expertise and device technology, complications associated with this catheter procedure are not uncommon. We report an unusual case of late contained rupture of the aortic annulus, combining a para‐aortic false aneurysm and a ventricular septal defect, after the placement of an Edwards Sapien prosthesis.Keywords
This publication has 6 references indexed in Scilit:
- One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) RegistryCirculation, 2011
- First‐in‐man transcatheter aortic valve implantation of a 20‐mm edwards SAPIEN XT valve: One step forward for the treatment of patients with severe aortic stenosis and small aortic annulusCatheterization and Cardiovascular Interventions, 2011
- Contained aortic root rupture after transcatheter aortic valve implantationEuropean Heart Journal, 2010
- Perforation of the Membranous Interventricular Septum After Transcatheter Aortic Valve ImplantationCirculation: Cardiovascular Interventions, 2009
- Transcatheter Aortic Valve ImplantationJACC: Cardiovascular Interventions, 2009
- Unexpected Complications of Transapical Aortic Valve ImplantationThe Annals of Thoracic Surgery, 2009