Thermal Performance Test of a Coaxial Double-Tube Hot-Gas Duct
Authors:
- 1 February 1994
- journal article
- research article
- Published by Taylor & Francis in Nuclear Technology
- Vol. 105 (2) , 293-299
Abstract
A coaxial double-tube hot-gas duct with an internal insulation layer is to be used for the High-Temperature Engineering Test Reactor (HTTR), a gas-cooled reactor designed by the Japan Atomic Energy Research Institute. A full-scale simulation of part of the hot-gas duct was constructed to verify its structural integrity. No hot spot was detected on the inner tube under HTTR operation conditions after 7700 h. Natural convection was negligible in the internal insulation layer. An experimental correlation of the effective thermal conductivity for the internal insulation layer was also obtained.Keywords
This publication has 5 references indexed in Scilit:
- Construction of in-core structure test section in HENDEL. (II). Testing devices and their performance tests.Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan, 1988
- Construction of in-core structure test section in HENDEL. (I). Outline of test section and simulated core bottom structure.Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan, 1988
- Thermal performance test of the hot gas ducts of HENDELNuclear Engineering and Design, 1984
- Insulation Systems for the Hot Gas Ducts of High Temperature Reactors and their Behavior at High Pressures and TemperaturesJournal of Non-Equilibrium Thermodynamics, 1978
- Free Convection Heat Transfer from a Vertical Surface to a Porous MediumTransactions of the Japan Society of Mechanical Engineers, 1968