Compressive sensing based Q-space resampling for handling fast bulk motion in hardi acquisitions
- 1 April 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 907-910
Abstract
Diffusion-weighted (DW) MRI has become a widely adopted imaging modality to reveal the underlying brain connectivity. Long acquisition times and/or non-cooperative patients increase the chances of motion-related artifacts. Whereas slow bulk motion results in inter-gradient misalignment which can be handled via retrospective motion correction algorithms, fast bulk motion usually affects data during the application of a single diffusion gradient causing signal dropout artifacts. Common practices opt to discard gradients bearing signal attenuation due to the difficulty of their retrospective correction, with the disadvantage to lose full gradients for further processing. Nonetheless, such attenuation might only affect limited number of slices within a gradient volume. Q-space resampling has recently been proposed to recover corrupted slices while saving gradients for subsequent reconstruction. However, few corrupted gradients are implicitly assumed which might not hold in case of scanning unsedated infants or patients in pain. In this paper, we propose to adopt recent advances in compressive sensing based reconstruction of the diffusion orientation distribution functions (ODF) with under sampled measurements to resample corrupted slices. We make use of Simple Harmonic Oscillator based Reconstruction and Estimation (SHORE) basis functions which can analytically model ODF from arbitrary sampled signals. We demonstrate the impact of the proposed resampling strategy compared to state-of-art resampling and gradient exclusion on simulated intra-gradient motion as well as samples from real DWI data.Keywords
This publication has 16 references indexed in Scilit:
- Subject–Motion Correction in HARDI Acquisitions: Choices and ConsequencesFrontiers in Neurology, 2014
- Correction strategy for diffusion-weighted images corrupted with motion: application to the DTI evaluation of infants' white matterMagnetic Resonance Imaging, 2014
- DTIPrep: quality control of diffusion-weighted imagesFrontiers in Neuroinformatics, 2014
- Continuous diffusion signal, EAP and ODF estimation via Compressive Sensing in diffusion MRIMedical Image Analysis, 2013
- Differences in White Matter Fiber Tract Development Present From 6 to 24 Months in Infants With AutismAmerican Journal of Psychiatry, 2012
- Volumetric navigators for real‐time motion correction in diffusion tensor imagingMagnetic Resonance in Medicine, 2012
- Diffusion imaging with prospective motion correction and reacquisitionMagnetic Resonance in Medicine, 2011
- Circos: An information aesthetic for comparative genomicsGenome Research, 2009
- Robust determination of the fibre orientation distribution in diffusion MRI: Non-negativity constrained super-resolved spherical deconvolutionNeuroImage, 2007
- Characterization of anisotropy in high angular resolution diffusion‐weighted MRIMagnetic Resonance in Medicine, 2002