As an important movement of the daily living activities, sit-to-stand (STS) movement is usually a difficult task facing elderly and dependent people. To provide appropriate power assistance for the sit-to-stand movement, a novel intention-based Active Impedance Control (AIC) strategy applied on a lower limb exoskeleton is proposed in this paper. The AIC is able to adapt the mechanical impedance of the human-exoskeleton system towards a desired one using the exoskeleton's power assistance. In the AIC structure, a human joint torque observer is designed to estimate the human joint torques using joint angles information instead of electromyography (EMG) or force/torque sensors; a time-varying desired impedance model is proposed according the wearer's lower limb motion ability. Simulations were implemented to illustrate the characteristics and performances of the proposed approach. Experiments with a healthy subject were carried out to evaluate the effectiveness of the proposed method. The experiments show satisfactory results in terms of appropriate power assist based on the wearer's motion intention.Keywords
This publication has 14 references indexed in Scilit:
- Nonlinear Disturbance Observer-Based Dynamic Surface Control of Mobile Wheeled Inverted PendulumIEEE Transactions on Control Systems Technology, 2015
- Real-Time EMG Driven Lower Limb Actuated Orthosis for Assistance As Needed Movement Strategy2013
- Design and Analysis of Force-Sensor-Less Power-Assist ControlIEEE Transactions on Industrial Electronics, 2013
- Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device2013
- Nonlinear disturbance observer design for robotic manipulatorsControl Engineering Practice, 2013
- Sit-to-Stand movement assistance using an actuated knee joint orthosis2012
- Sit-to-Stand and Stand-to-Sit Transfer Support for Complete Paraplegic Patients with Robot Suit HALAdvanced Robotics, 2010
- Control of Exoskeletons Inspired by Fictitious Gain in Human ModelIEEE/ASME Transactions on Mechatronics, 2009
- FIVE TIMES SIT TO STAND TEST IS A PREDICTOR OF RECURRENT FALLS IN HEALTHY COMMUNITY‐LIVING SUBJECTS AGED 65 AND OLDERJournal of the American Geriatrics Society, 2008
- Adjustments to Zatsiorsky-Seluyanov's segment inertia parametersJournal of Biomechanics, 1996