Verification of quality parameters for portal images in radiotherapy
Authors:
Open Access
- 1 January 2011
- journal article
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 45 (1) , 68-74
Abstract
The purpose of the study was to verify different values of quality parameters of portal images in radiotherapy. We investigated image qualities of different field verification systems. Four EPIDs (Siemens OptiVue500aSi(®), Siemens BeamView Plus(®), Elekta iView(®) and Varian PortalVision™) were investigated with the PTW EPID QC PHANTOM(®) and compared with two portal film systems (Kodak X-OMAT(®) cassette with Kodak X-OMAT V(®) film and Kodak EC-L Lightweight(®) cassette with Kodak Portal Localisation ReadyPack(®) film). A comparison of the f50 and f25 values of the modulation transfer functions (MTFs) belonging to each of the systems revealed that the amorphous silicon EPIDs provided a slightly better high contrast resolution than the Kodak Portal Localisation ReadyPack(®) film with the EC-L Lightweight(®) cassette. The Kodak X-OMAT V(®) film gave a poor low contrast resolution: from the existing 27 holes only 9 were detectable. On the base of physical characteristics, measured in this work, the authors suggest the use of amorphous-silicon EPIDs producing the best image quality. Parameters of the EPIDs with scanning liquid ionisation chamber (SLIC) were very stable. The disadvantage of older versions of EPIDs like SLIC and VEPID is a poor DICOM implementation, and the modulation transfer function (MTF) values (f50 and f25) are less than that of aSi detectors.Keywords
This publication has 19 references indexed in Scilit:
- Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurementsRadiology and Oncology, 2010
- A fully electronic intensity-modulated radiation therapy quality assurance (IMRT QA) process implemented in a network comprised of independent treatment planning, record and verify, and delivery systemsRadiology and Oncology, 2010
- Optimization of image quality and dose for Varian aS500 electronic portal imaging devices (EPIDs)Physics in Medicine & Biology, 2007
- Routine individualised patient dosimetry using electronic portal imaging devicesRadiotherapy and Oncology, 2007
- Digitalization and Networking of Analog Simulators and Portal ImagesStrahlentherapie und Onkologie, 2007
- Implementing of the offline setup correction protocol in pelvic radiotherapy: safety margins and number of imagesRadiology and Oncology, 2007
- Portal Verification Using the KODAK ACR 2000 RT Storage Phosphor Plate System and EC® FilmsStrahlentherapie und Onkologie, 2006
- Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imagerMedical Physics, 2001
- Dosimetric characteristics of a liquid-filled electronic portal imaging deviceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995
- A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapyRadiotherapy and Oncology, 1988