Illustrations reduce contamination of midstream urine samples in the emergency department
- 18 February 2016
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 69 (10) , 921-925
Abstract
Aims Urinalysis provides direction in diagnosis and treatment of patients in the emergency department (ED). Midstream urine (MSU) collection from female patients has a high contamination rate. Verbal instruction by nurses to patients reduces contamination but is inconsistent owing to lack of time and professional knowledge. This study aimed to determine if an alternative mode of instruction requiring minimal staff input may be effective. Methods A pseudorandomised controlled trial was undertaken with 240 female patients for whom urinalysis was clinically required. No change was made to normal practice with regards to verbal instruction. Prior to collecting their sample the intervention cohort received illustrated instruction on how to collect a clean uncontaminated MSU sample. The control cohort received no illustrated instruction. Compared outcomes were rate of contamination on urinalysis, defined as 10 or more epithelial cells per high power field, and answers to a structured patient questionnaire. Results Contamination rate was reduced from 40% to 25% by the intervention. According to patient survey responses, verbal collection instructions were seldom given and the actions of hand washing, cleaning with a towelette, and voiding then stopping were significantly higher in the intervention group. The illustrations were well received by over 95% of patients and were considered to be clear and effective especially for patients with reading difficulties and/or from a non-English speaking background. Conclusions Illustrated urine collection instructions were well accepted by female ED patients, improved the rate of proper MSU collection and reduced the rate of urinalysis contamination in the ED.Keywords
This publication has 17 references indexed in Scilit:
- Contamination rates of different urine collection methods for the diagnosis of urinary tract infections in young children: An observational cohort studyJournal of Paediatrics and Child Health, 2012
- Urine Collection in the Emergency Department: What Really HappensWestern Journal of Emergency Medicine, 2011
- Cost effectiveness of management strategies for urinary tract infections: results from randomised controlled trialBMJ, 2010
- Effect of Perineal Cleansing on Contamination Rate of Mid-stream Urine CultureJournal of Pediatric and Adolescent Gynecology, 2006
- Urinary tract infections in women: diagnosis and management in primary careBMJ, 2006
- A novel midstream urine‐collection device reduces contamination rates in urine cultures amongst womenBJU International, 2005
- Written and verbal information versus verbal information only for patients being discharged from acute hospital settings to home: systematic reviewHealth Education Research, 2004
- A selective review of the literature on nurse‐patient communication: has the patient's contribution been neglected'Journal of Advanced Nursing, 1995
- Does a Clean-Catch Urine Sample Reduce Bacterial Contamination?New England Journal of Medicine, 1993
- Collection of a clean voided urine specimen: a comparison among spoken, written, and computer-based instructions.American Journal of Public Health, 1977