Abstract
To measure water pressure at any depth (including depths below 5 to 7 m) in the vadose zone and groundwater, a two-cell, omni-depth tensiometer has been developed. Water level in the lower cell in this tensiometer is maintained at a relatively constant height above the porous tip. An isolated volume of air above the water level in the lower cell changes air pressure in proportion to the water pressure changes of the soils that surround the tensiometer porous tip. The upper cell replenishes water in the lower cell when needed. Several tensiometers can be installed at different depths in boreholes. The air pressure is measured in both cells remotely above the land surface. The tensiometer can be used for long-term monitoring of negative pressure under drying and wetting cycles in the vadose zone and for monitoring of positive pressure below the water table. This paper describes a tensiometer design and the results of testing the tensiometer models.