Evaluation of renovated double J stents using ureter models with and without stenosis
- 10 April 2024
- journal article
- research article
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-7
Abstract
Purpose Commercial double J stents (DJS) have a uniform shape regardless of the specific nature of various ureteral diseases. We tested renovated DJS and compared them with conventional DJS using ureter models. Methods One straight ureter model included stenosis at the distal ureter near the ureterovesical junction and the other did not. We used conventional DJS and renovated 5- and 6-Fr soft DJS for ureter stones and 6-, 7-, and 8.5-Fr hard DJS for tumors. The DJS comprised holes in the upper, middle, or lower one-third of the shaft (length, 24 cm; 2-cm-diameter coils at both ends). More holes were created along the shaft based on the ureteral disease location. Conventional DJS had holes spaced 1 cm apart along the shaft. Renovated DJS had holes spaced 1 cm apart along the shaft with 0.5-cm intervals on the upper, middle, or lower one-third of the shaft. Urine flow was evaluated. Results As the DJS diameter increased, the flow rate decreased. The flow rates of DJS with holes in the lower shaft were relatively lower than those of conventional DJS and DJS with holes in the upper and middle shafts. In the ureter model without stenosis, 6-, 7-, and 8.5-Fr renovated stents exhibited significantly higher flow rates than conventional stents. In the ureter model with stenosis, 5-, 6-, 7-, and 8.5-Fr renovated stents did not exhibit significantly higher flow rates than conventional stents. Conclusion Renovated stents and conventional stents did not exhibit significant differences in urine flow with stenosis.Keywords
Funding Information
- National Research Foundation of Korea (2021R1F1A1051004)
This publication has 20 references indexed in Scilit:
- Fluid mechanical modeling of the upper urinary tractWIREs Mechanisms of Disease, 2021
- Double J Stenting - Clinical Profile, Indications and Post Operative ComplicationsMVP Journal of Medical Science, 2021
- Urine drainage management in colorectal surgeryJournal of Visceral Surgery, 2020
- Strategies to Improve Patient Outcomes and QOL: Current Complications of the Design and Placements of Ureteric StentsResearch and Reports in Urology, 2020
- Arrangement of side holes in a double J stent for high urine flow in a stented ureterJournal of Mechanical Science and Technology, 2020
- Urine flow analysis using double J stents of various sizes in in vitro ureter modelsInternational Journal for Numerical Methods in Biomedical Engineering, 2020
- Advances in Ureteral Stent Design and MaterialsCurrent Urology Reports, 2018
- Analysis of Urine Flow in Three Different Ureter ModelsComputational and Mathematical Methods in Medicine, 2017
- Investigating the Flow Dynamics in the Obstructed and Stented Ureter by Means of a Biomimetic Artificial ModelPLOS ONE, 2014
- Comparison of a biodegradable ureteral stent versus the traditional double-J stent for the treatment of ureteral injury: an experimental studyBiomedical Materials, 2012