Using linear and non‐parametric regression models to describe the contribution of non‐linear loads on the voltage harmonic distortions in the electrical grid
Open Access
- 1 May 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 10 (8) , 1825-1832
Abstract
This study addresses the problem of determining which non‐linear loads can be considered potential harmonic sources to the voltage harmonic distortions observed in the utility grid voltages. Statistical regression models are used to establish correlations between the simultaneously measured harmonic voltages, in the grid, and harmonic currents, at each non‐linear individual load. First, the R ‐squared statistic is used to decide the goodness of fit of the developed models, giving indication on the relevance of the model. In order to overcome the limitation of the linear regression model based on voltage and current magnitudes measurements only, that imposes a constant behaviour for the background harmonic sources, a non‐parametric regression model is suggested and a comparison between the performances of the two models is carried out. Field data from two real electrical systems, one having a 138 kV substation in which a large industrial load and a 34.5 kV rural long feeder are connected; and the other having four urban 13.8 kV feeders supplying industrial and commercial loads, were used to develop and validate the statistical models used in the application.Keywords
This publication has 18 references indexed in Scilit:
- A method for determination of harmonics responsibilities at the point of common coupling using data correlation analysisIET Generation, Transmission & Distribution, 2014
- Modified superposition method for assignment of responsibilities on harmonic distortions2011
- INTRODUCTORY STATISTICS2010
- Estimation of the Utility's and Consumer's Contribution to Harmonic DistortionIEEE Transactions on Instrumentation and Measurement, 2009
- A “Critical Impedance”-Based Method for Identifying Harmonic SourcesIEEE Transactions on Power Delivery, 2004
- An investigation on the validity of power-direction method for harmonic source determinationIEEE Transactions on Power Delivery, 2003
- A method for determining customer and utility harmonic contributions at the point of common couplingIEEE Transactions on Power Delivery, 2000
- Harmonic pollution metering: theoretical considerationsIEEE Transactions on Power Delivery, 2000
- On techniques for localization of sources producing distortion in three‐phase networksEuropean Transactions on Electrical Power, 1996
- Harmonic power flow analysis for the measurement of the electric power qualityIEEE Transactions on Instrumentation and Measurement, 1995