Automatic measurement of kidney dimensions in two-dimensional ultrasonography is comparable to expert sonographers
- 1 May 2023
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (03) , 034003-9
Abstract
PurposeLength and width measurements of the kidneys aid in the detection and monitoring of structural abnormalities and organ disease. Manual measurement results in intra- and inter-rater variability, is complex and time-consuming, and is fraught with error. We propose an automated approach based on machine learning for quantifying kidney dimensions from two-dimensional (2D) ultrasound images in both native and transplanted kidneys.ApproachAn nnU-net machine learning model was trained on 514 images to segment the kidney capsule in standard longitudinal and transverse views. Two expert sonographers and three medical students manually measured the maximal kidney length and width in 132 ultrasound cines. The segmentation algorithm was then applied to the same cines, region fitting was performed, and the maximum kidney length and width were measured. Additionally, single kidney volume for 16 patients was estimated using either manual or automatic measurements.ResultsThe experts resulted in length of 84.8 ± 26.4 mm [95% CI: 80.0, 89.6] and a width of 51.8 ± 10.5 mm [49.9, 53.7]. The algorithm resulted a length of 86.3 ± 24.4 [81.5, 91.1] and a width of 47.1 ± 12.8 [43.6, 50.6]. Experts, novices, and the algorithm did not statistically significant differ from one another (p > 0.05). Bland–Altman analysis showed the algorithm produced a mean difference of 2.6 mm (SD = 1.2) from experts, compared to novices who had a mean difference of 3.7 mm (SD = 2.9 mm). For volumes, mean absolute difference was 47 mL (31%) consistent with ∼1 mm error in all three dimensions.ConclusionsThis pilot study demonstrates the feasibility of an automatic tool to measure in vivo kidney biometrics of length, width, and volume from standard 2D ultrasound views with comparable accuracy and reproducibility to expert sonographers. Such a tool may enhance workplace efficiency, assist novices, and aid in tracking disease progression.Keywords
This publication has 18 references indexed in Scilit:
- Total Kidney Volume in Autosomal Dominant Polycystic Kidney Disease: A Biomarker of Disease Progression and Therapeutic EfficacyAmerican Journal of Kidney Diseases, 2015
- A comparison of ultrasound and magnetic resonance imaging shows that kidney length predicts chronic kidney disease in autosomal dominant polycystic kidney diseaseKidney International, 2015
- Ultrasonographic renal volume measurements in early autosomal dominant polycystic disease: Comparison with CT-scan renal volume calculationsDiagnostic and Interventional Imaging, 2015
- ACR Appropriateness Criteria® on Renal FailureThe American Journal of Medicine, 2014
- Usefulness of Renal Volume Measurements Obtained by a 3-Dimensional Sonographic Transducer With Matrix Electronic ArraysJournal of Ultrasound in Medicine, 2008
- The role of ultrasonography in the study of medical nephropathyJournal of Ultrasound, 2007
- Normal Values for Renal Length and Volume as Measured by Magnetic Resonance ImagingClinical Journal of the American Society of Nephrology, 2007
- Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR ImagingRadiology, 1999
- In vitro measurement of kidney size: comparison of ultrasonography and MRIUltrasound in Medicine & Biology, 1998
- Kidney dimensions at sonography: correlation with age, sex, and habitus in 665 adult volunteers.American Journal of Roentgenology, 1993