Reference Ranges of Blood Flow in the Major Vessels of the Normal Human Fetal Circulation at Term by Phase-Contrast Magnetic Resonance Imaging
Top Cited Papers
- 1 July 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 7 (4) , 663-670
Abstract
Background—: Phase-contrast MRI with metric-optimized gating is a promising new technique for studying the distribution of the fetal circulation. However, mean and reference ranges for blood flow measurements made in the major fetal vessels using this technique are yet to be established. Methods and Results—: We measured flow in the major vessels of the fetal circulation in 40 late-gestation normal human fetuses using phase-contrast MRI (mean gestational age, 37 [SD=1.1] weeks). Flows were indexed to the fetal weight, which was estimated from the fetal volume calculated by MRI segmentation. The following mean flows (in mL/min per kilogram; ±2SD) were obtained: combined ventricular output, 465 (351, 579); main pulmonary artery, 261 (169, 353); ascending aorta, 191 (121, 261); superior vena cava, 137 (77, 197); ductus arteriosus, 187 (109, 265); descending aorta, 252 (160, 344); pulmonary blood flow, 77 (0, 160); umbilical vein, 134 (62, 206); and foramen ovale, 135 (37, 233). Expressed as percentages of the combined ventricular output, the mean flows±2 SD were as follows: main pulmonary artery, 56 (44, 68); ascending aorta, 41 (29, 53); superior vena cava, 29 (15, 43); ductus arteriosus, 41 (25, 57); descending aorta, 55 (35, 75); pulmonary blood flow, 16 (0, 34); umbilical vein, 29 (11, 47); and foramen ovale, 29 (7, 51). A strong inverse relationship between foramen ovale shunt and pulmonary blood flow was noted ( r =−0.64; P <0.0001). Conclusions—: Although too small a sample size to provide normal ranges, these results are in keeping with those predicted in humans based on measurements made in fetal lambs using radioactive microspheres and provide preliminary reference ranges for the late-gestation human fetuses. The wide range we found in foramen ovale shunting suggests a degree of variability in the way blood is streamed through the fetal circulation.Keywords
This publication has 30 references indexed in Scilit:
- Fetal circulation in left-sided congenital heart disease measured by cardiovascular magnetic resonance: a case–control studyJournal of Cardiovascular Magnetic Resonance, 2013
- Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart diseaseJournal of Cardiovascular Magnetic Resonance, 2013
- Cardiac MRI of the fetal heart using a novel triggering method: Initial results in an animal modelJournal of Magnetic Resonance Imaging, 2012
- Metric optimized gating for fetal cardiac MRIMagnetic Resonance in Medicine, 2010
- In vivo MRI measurement of fetal blood oxygen saturation in cardiac ventricles of fetal sheep: A feasibility studyMagnetic Resonance in Medicine, 2010
- Fetal cardiac output, distribution to the placenta and impact of placental compromiseUltrasound in Obstetrics & Gynecology, 2006
- In Vivo Validation of Magnetic Resonance Blood Volume Flow Measurements with Limited Spatial Resolution in Small VesselsMagnetic Resonance in Medicine, 1995
- Assessment of changes in blood flow through the lungs and foramen ovale in the normal human fetus with gestational age: a prospective Doppler echocardiographic study.Heart, 1994
- Fetal cardiac output estimated by Doppler echocardiography during mid- and late gestationThe American Journal of Cardiology, 1987
- A fast algorithm for nonlinearly constrained optimization calculations1978